{"product_id":"abb-pftl-101b-3bse004191r1-pressductor-load-cell","title":"ABB PFTL 101B 3BSE004191R1 Pressductor Load Cell","description":"\u003cp\u003eThe \u003cstrong\u003eABB PFTL101B 3BSE004191R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePFTL101B\u003c\/strong\u003e Load Cell, operates as a dedicated hardware component for tension measurement, weight monitoring, and force detection within ABB Pressductor processing platforms. Utilizing magnetoelastic Pressductor sensor technology, the unit converts applied mechanical forces across a 0 to 5.0 kN measuring range into a 2 mV\/V electrical output signal with an accuracy of +\/-0.1% of full scale. Powered by an excitation voltage of 10 to 30 V DC, the stainless steel and alloy steel housing provides IP67 protection across an operating temperature range from -10 deg C to +50 deg C.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePFTL101B (3BSE004191R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003ePFTL101B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eCompact Chassis Load Cell Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact Subrack \/ Pillow Block Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven by 10 to 30 V DC Excitation Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5.0 kN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e2 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel and alloy steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Technology\u003c\/td\u003e\n\u003ctd\u003eMagnetoelastic Pressductor principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe raw millivolt signal generated by the load cell routes to connected ABB evaluation units, maintaining rapid backplane bus communication velocity during real-time digitizing sequences. Electromagnetic excitation of the internal core structure enables high-frequency signal sampling without mechanical strain gauge fatigue, supporting high I\/O density scaling across multi-axis web systems. Local controller firmware flash compatibility permits direct loading of non-linear calibration matrices and dynamic temperature compensation profiles over local bus connections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the physical measurement axis oriented during mechanical mounting?\u003c\/p\u003e\n\u003cp\u003eA: The load cell chassis must be mounted flat against the bearing support plate, ensuring the applied mechanical load vector aligns directly with the force axis marked on the housing.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions should be observed when connecting excitation power?\u003c\/p\u003e\n\u003cp\u003eA: Ensure the excitation power supply voltage remains strictly within the specified 10 to 30 V DC limits. Exceeding maximum excitation limits may cause internal thermal heating and alter sensor output accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that mounting foundation surfaces are planar, rigid, and free of dirt, metal filings, or corrosion prior to positioning the unit.\u003c\/li\u003e\n\u003cli\u003eTorque all mounting bolts evenly in a cross pattern to manufacturer recommendations to prevent localized stress concentration on the sensor body.\u003c\/li\u003e\n\u003cli\u003eConnect signal and excitation cabling using twisted shielded pairs to mitigate high-frequency electrical noise from surrounding motor drives.\u003c\/li\u003e\n\u003cli\u003eGround all cable shields at a single point on the central cabinet earthing bar to prevent ground loops from disturbing the 2 mV\/V analog signal.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53227262116149,"sku":"PFTL 101B 3BSE004191R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PFTL101B3BSE004191R1.png?v=1785382143","url":"https:\/\/www.5gplc.com\/products\/abb-pftl-101b-3bse004191r1-pressductor-load-cell","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}