{"product_id":"abb-nkas01-15-infi-90-analog-module-termination-unit-cable","title":"ABB NKAS01-15 INFI 90 Analog Module Termination Unit Cable","description":"\u003cp\u003eThe \u003cstrong\u003eABB NKAS01-15\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNKAS01\u003c\/strong\u003e Analog Module Termination Unit Cable, operates as a dedicated hardware component for analog signal interface routing within ABB Bailey INFI 90 and Symphony control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNKAS01-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Europe standard sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15 ft (4.57 m) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical media communication loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Module Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Depth\u003c\/td\u003e\n\u003ctd\u003e53.34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Height\u003c\/td\u003e\n\u003ctd\u003e342.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Width\u003c\/td\u003e\n\u003ctd\u003e304.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB NKAS01-15\u003c\/strong\u003e establishes a stable physical link layer to execute analog signal processing and interface matching across Bailey termination topologies. The continuous line impedance parameters prevent dropouts during high-frequency data conversions on sequential analog channels. By maintaining high signal isolation profiles across the integrated copper conductors, the assembly manages dense I\/O density scaling routines inside multi-rack panels while enforcing direct noise containment, eliminating timing delays and preserving total firmware flash compatibility with upstream automation node controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does removing or plugging this termination cable while the analog module is energized affect system operations?\u003c\/p\u003e\n\u003cp\u003eA: This is a passive media interconnect; however, uncoupling the cable during runtime operations instantly cuts the continuous 4-20 mA field measurement path, forcing the associated analog input channels into an open-circuit fault state inside the controller software.\u003c\/p\u003e\n\u003cp\u003eQ: How should system grounds be distributed across this analog termination assembly?\u003c\/p\u003e\n\u003cp\u003eA: Structural shield common lines must map directly to the system cabinet instrument ground bar. Ensure terminal connections comply with standard zero-potential isolation paths to prevent ground loops across differential input channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the cable assembly within protected wiring raceways, securing it at standard structural boundaries to remove mechanical stress from the connector pins.\u003c\/li\u003e\n\u003cli\u003eMaintain distinct segregation pathways between this analog signal trunk and neighboring high-voltage AC\/DC power infrastructure to limit inductive interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the routing trajectory complies with the minimum bending radius of the cable jacket to prevent copper strain or foil shield degradation.\u003c\/li\u003e\n\u003cli\u003eSeat the interface plugs fully into the socket housings on both the module backplane and termination unit before clicking any physical mechanical latches home.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53085080551733,"sku":"NKAS01-15","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NKAS01-15.png?v=1783060586","url":"https:\/\/www.5gplc.com\/products\/abb-nkas01-15-infi-90-analog-module-termination-unit-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}