{"product_id":"abb-icso-16-n1-fpr3313101r0056-binary-output-module","title":"ABB ICSO 16 N1 FPR3313101R0056 Binary Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB ICSO 16 N1 FPR3313101R0056\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eICSO 16 N1\u003c\/strong\u003e Binary Output Module, operates as a dedicated hardware component for high-voltage discrete switching within ABB automation control platforms. It processes 220 VAC binary signals across 16 channels to drive actuators, solenoids, interposing relays, and status indicators directly from controller bus commands.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eICSO 16 N1 (FPR3313101R0056)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBinary Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels (220 VAC, 16-fold execution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e220 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rack module form factor (Gross volume 1.67 dm3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane and external field voltage dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSubrack slot insertion \/ terminal unit mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Deterministic Switching\u003c\/h3\u003e\n\u003cp\u003eThe module maintains synchronized backplane communications with the main controller to process output state updates without signal latency. Built-in logic execution circuits evaluate field feedback states against internal register commands before switching output stages. Internal status flags and firmware flash compatibility enable non-volatile storage of channel configuration states, ensuring controlled state retention or default fail-safe de-energization in the event of backplane bus interruptions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module require an external voltage supply for channel operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the output contacts route external 220 VAC utility power to field devices, while the module logic interface draws operating power from the system rack backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output circuit faults or overcurrent conditions?\u003c\/p\u003e\n\u003cp\u003eA: Each output circuit is designed for load isolation, preventing field short circuits or line spikes from traveling back to the central controller backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower Isolation: Disconnect all 220 VAC external field power sources and rack supply power before inserting or removing the module from the mounting assembly.\u003c\/li\u003e\n\u003cli\u003eMechanical Seating: Align the printed circuit board edges with the slot guide rails and push firmly until the backplane interface connectors are fully engaged.\u003c\/li\u003e\n\u003cli\u003eWiring Separation: Route 220 VAC high-voltage output cables in dedicated wire trunks separate from low-voltage DC communication lines to eliminate capacitive cross-talk and inductive noise.\u003c\/li\u003e\n\u003cli\u003eGrounding Protocol: Connect shield drains and panel enclosure grounds directly to the central earth ground bus bar using short, low-impedance grounding conductors.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53256914305333,"sku":"ICSO 16 N1 FPR3313101R0056","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ICSO16N1.png?v=1786066337","url":"https:\/\/www.5gplc.com\/products\/abb-icso-16-n1-fpr3313101r0056-binary-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}