{"product_id":"abb-gd9924be-v2-hiee401091r0002-digital-input-module","title":"ABB GD9924BE,V2 HIEE401091R0002 Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB GD9924BE,V2 HIEE401091R0002\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eGD9924BE,V2\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for high-speed discrete state acquisition and signal isolation within RobotWare controller architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGD9924BE,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHIEE401091R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e38.2 cm x 12.7 cm x 6.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eScalable Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eDual-port integrated switch for daisy chaining\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eChange of State (CoS) fast signal detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail \/ Controller internal mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe GD9924BE,V2 integrates a dual-port Ethernet switch interface to facilitate daisy-chain network topologies across scalable I\/O nodes without additional hardware switches. Supporting deterministic bus communication velocity through Change of State (CoS) triggering, the module transmits field input status changes immediately across the backplane bus to minimize controller response latencies. Galvanic isolation across input channels protects internal processing circuits from field-side voltage transients and loop interference, while maintaining high I\/O density scaling inside control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the GD9924BE,V2 support daisy-chain network configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module includes an integrated dual-port Ethernet switch that enables direct daisy-chaining between adjacent I\/O units, reducing cable routing requirements within or outside the controller cabinet.\u003c\/p\u003e\n\u003cp\u003eQ: How does Change of State (CoS) signal processing function on this digital input module?\u003c\/p\u003e\n\u003cp\u003eA: Rather than relying solely on fixed cyclical polling, Change of State logic immediately triggers data transmissions upon detecting an input state transition, accelerating signal transfer speeds to the master controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMounting: Snap the module firmly onto a standard 35 mm DIN rail inside the controller cabinet or at a distributed external junction box. Ensure the DIN-rail locking mechanism is fully engaged.\u003c\/li\u003e\n\u003cli\u003eWiring Isolation: Route digital input signal cables through dedicated wire channels separated from high-voltage AC motor power lines to minimize induced electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eNetwork Cabling: Connect Ethernet cables to the dual-port switch interfaces using shielded RJ45 connectors. Verify that minimum cable bend radius limits are respected during installation.\u003c\/li\u003e\n\u003cli\u003eGrounding: Connect the module chassis shielding to the main functional earth (FE) bus bar using low-impedance grounding connections to maintain galvanic isolation performance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53227690426677,"sku":"GD9924BE,V2 HIEE401091R0002","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/GD9924BE_V2HIEE401091R00022.png?v=1785397404","url":"https:\/\/www.5gplc.com\/products\/abb-gd9924be-v2-hiee401091r0002-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}