{"product_id":"abb-dsrc-113-52820083-lf-fan-unit","title":"ABB DSRC 113 52820083-LF Fan Unit","description":"\u003cp\u003eThe \u003cstrong\u003eABB DSRC 113 52820083-LF\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDSRC 113\u003c\/strong\u003e Fan Unit, operates as a dedicated hardware component for forced-air thermal management within industrial automation chassis enclosures. The unit directly executes physical heat dissipation sequences by driving internal fan assemblies via a 24 VDC electrical input.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSRC 113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e52820083-LF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExchange Part Number\u003c\/td\u003e\n\u003ctd\u003e7650 055-357\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.710 kg net \/ 3.710 kg gross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard industrial subrack enclosure footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Standard baseline for enclosure cooling hardware)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption \/ Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Complement\u003c\/td\u003e\n\u003ctd\u003e1x DSRC 001 (52820090-A), 3x Fans (6480096-9), 1x Fuse (56722011-17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Option\u003c\/td\u003e\n\u003ctd\u003e1x Air Filter (3BSC930057R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Networks \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe unit establishes local circuit tracking to maintain internal subrack operational stability. Unlike active computing modules processing data over Profinet \/ EtherNet\/IP deterministic networks, this hardware regulates physical airspeed parameters without executing high-level software instructions. The internal terminal connections maintain direct electrical compliance metrics to preserve backplane bus communication velocity licenses across adjacent computing cards while ensuring immediate hardware framework integration during firmware flash compatibility adjustments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can single internal fans be individualistically replaced during live system operation?\u003c\/p\u003e\n\u003cp\u003eA: No. S500\/Advant subrack layout rules dictate that servicing internal sub-components like the 6480096-9 fans requires isolation of the 24 VDC power rail to prevent transient electrical shorts or injuries from mechanical rotational elements.\u003c\/p\u003e\n\u003cp\u003eQ: What protection parameter does the internal 56722011-17 fuse enforce?\u003c\/p\u003e\n\u003cp\u003eA: The integrated fuse serves as an over-current suppression threshold on the incoming 24 VDC power bus, isolating the internal DSRC 001 terminal board if any fan motor experiences a locked-rotor fault condition.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 3BSC930057R1 air filter mandatory for standard operation?\u003c\/p\u003e\n\u003cp\u003eA: The air filter is an optional component designed for deployment in high-particulate air profiles to limit debris accumulation on adjacent active electronic card boundaries.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSlide the assembly into the designated enclosure tray slot, verifying structural alignment with the primary mounting channels prior to finalizing mechanical retention.\u003c\/li\u003e\n\u003cli\u003eConnect the input power lines to the 24 VDC source, observing explicit polarity conventions to prevent backwards airflow distribution profile changes.\u003c\/li\u003e\n\u003cli\u003eEnsure a physical separation of at least 100 mm between the DC power input wires and high-voltage AC lines to mitigate inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003ePerform monthly inspections of the optional air filter element to prevent blockage conditions from reducing convective volumetric flow rates below the specification floor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53054447976757,"sku":"DSRC 113 52820083-LF","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DSRC11252820083-GD_01020605-ae93-4579-af51-876427991803.png?v=1782897142","url":"https:\/\/www.5gplc.com\/products\/abb-dsrc-113-52820083-lf-fan-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}