{"product_id":"abb-dsqc-658-3hac037084-001-devicenet-board","title":"ABB DSQC 658 3HAC037084-001 DeviceNet Board","description":"\u003cp\u003eConfigured for high-speed industrial network interfacing within IRC5 controller platforms, the \u003cstrong\u003eABB DSQC 658\u003c\/strong\u003e (\u003cstrong\u003e3HAC037084-001\u003c\/strong\u003e DeviceNet Board) provides direct physical signal transmission and data communication protocol execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSQC 658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3HAC037084-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 mm x 130 mm x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Requirement\u003c\/td\u003e\n\u003ctd\u003eRW 5.13 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/h3\u003e\n\u003cp\u003eThe DSQC 658 facilitates deterministic data exchange within the IRC5 architecture, ensuring low-latency communication between the controller and DeviceNet field devices. The hardware integration requires RobotWare 5.13 or later to ensure proper firmware flash compatibility and register mapping. Field bus synchronization is handled through the dedicated backplane bus communication velocity architecture, which minimizes jitter in cyclic data transfers. Users must verify that the master configuration file matches the slave device node address and baud rate settings to maintain network integrity and prevent bus-off states.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this board compatible with RobotWare versions earlier than 5.13?\u003c\/p\u003e\n\u003cp\u003eA: No, firmware architecture within the DSQC 658 requires a minimum of RobotWare 5.13 to initiate the communication stack and hardware handshake successfully.\u003c\/p\u003e\n\u003cp\u003eQ: Does the board support hot-swapping during active controller operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Any hardware modification or insertion must be performed while the control system is powered down to prevent damage to the backplane connectors and signal logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Precautions\u003c\/strong\u003e: Always wear an ESD-compliant wrist strap connected to a common ground point when handling the PCB to prevent discharge damage to sensitive IC components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting\u003c\/strong\u003e: Ensure the board is seated firmly within the designated controller slot. Tighten the retaining screws to the specified torque to guarantee a stable electrical connection to the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: DeviceNet cables must utilize twisted-pair cabling with adequate shielding. Ensure the shield is grounded at a single point, ideally at the power supply or the designated cabinet grounding lug, to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination\u003c\/strong\u003e: Install a 121 ohm 0.25 W resistor at both ends of the DeviceNet trunk line to suppress signal reflections and maintain characteristic impedance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Maintain physical separation between DeviceNet communication lines and high-voltage power cables to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52965377147189,"sku":"DSQC 658 3HAC037084-001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DSQC6583HAC037084-001.png?v=1780641121","url":"https:\/\/www.5gplc.com\/products\/abb-dsqc-658-3hac037084-001-devicenet-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}