{"product_id":"abb-dscs-116-57520001-bz-communication-module","title":"ABB DSCS 116 57520001-BZ Communication Module","description":"\u003cp\u003eConfigured for synchronous data routing in Advant Master architectures, the \u003cstrong\u003eABB DSCS 116 57520001-BZ\u003c\/strong\u003e (\u003cstrong\u003eDSCS 116\u003c\/strong\u003e Communication Module) provides direct physical\/electrical execution of time-critical inter-rack frame synchronization. The hardware manages precise bit-stream sequencing across localized network channels to prevent phase displacement between coupled processing subracks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSCS 116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e57520001-BZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot circuit board footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C (Standard backplane deployment baseline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSustained via backplane distribution rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Performance\u003c\/td\u003e\n\u003ctd\u003eSynchronous physical-layer signal coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Networks \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe internal transceiver architecture maps frame buffers directly to the clock cycles defined by current backplane bus communication velocity licenses. This design maintains strict timing boundaries across Profinet \/ EtherNet\/IP deterministic networks, ensuring steady code execution and eliminating bit jitter during large-scale I\/O density scaling events. The interface circuits are structurally mapped to prevent communication timeouts, securing absolute firmware flash compatibility with adjacent master CPU nodes during system initialization phases.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the physical configuration of the DSCS 116 support on-line module replacement (hot-swapping)?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the subrack host must be fully isolated before inserting or extracting the board assembly. Attempting live removal can introduce transient noise into the parallel bus layout, violating active backplane bus communication velocity licenses and forcing local controllers into error states.\u003c\/p\u003e\n\u003cp\u003eQ: How is synchronous phase deviation handled by the hardware interface?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on exact hardware-level clock cycles distributed through the backplane traces. If a timing fault occurs, the internal transceivers halt the message frame to stop corruption from spreading across the deterministic network loop.\u003c\/p\u003e\n\u003cp\u003eQ: Does this component require a localized firmware upload during on-site installation?\u003c\/p\u003e\n\u003cp\u003eA: The module operates based on embedded hardware logic pathways. Compatibility matches the baseline hardware index of the active controller chassis, requiring confirmation of matching firmware flash compatibility layers before commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSlide the circuit card evenly along the chassis alignment channels until the rear connector block sits fully into the subrack backplane receiver.\u003c\/li\u003e\n\u003cli\u003eMaintain a clearance of at least 100 mm between external communication lines and local high-voltage AC electrical distribution tracks to eliminate inductive coupling.\u003c\/li\u003e\n\u003cli\u003eSecure the front panel retention fasteners to anchor the board faceplate against the frame, providing low-resistance ground continuity and damping vibration stress.\u003c\/li\u003e\n\u003cli\u003eGround all communication screen braids continuously at the central panel copper ground terminal strip to block high-frequency industrial interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53054535926069,"sku":"DSCS 116 57520001-BZ","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DSCS11657520001-BZ.png?v=1782901027","url":"https:\/\/www.5gplc.com\/products\/abb-dscs-116-57520001-bz-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}