{"product_id":"abb-dsbb-110a-57330001-y-advant-master-shield-board","title":"ABB DSBB 110A 57330001-Y Advant Master Shield Board","description":"\u003cp\u003eThe \u003cstrong\u003eABB 57330001-Y\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDSBB 110A\u003c\/strong\u003e Shield Board, operates as a dedicated hardware component for electromagnetic interference suppression and logic sub-assembly processing within ABB Advant Master platforms. The board mounts directly into the main controller subrack to maintain signal integrity across parallel processing data pathways while managing high-speed system register updates.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSBB 110A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e57330001-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C (Standard industrial baseline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived from primary rack backplane power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eExempt from the scope of 2011\/65\/EU (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eMulti-language programmable CPU function with integrated flash memory allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Controller Interface\u003c\/h3\u003e\n\u003cp\u003eThe hardware assembly pairs directly with host processing nodes to coordinate multi-channel data operations. System resource allocations are verified via internal routine checks linked to backplane bus communication velocity licenses. This structural interface enforces strict firmware flash compatibility parameters upon system initialization, ensuring stable code execution across the integrated network communication modules without introducing latency to data transfer intervals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DSBB 110A hardware platform support online hot-swapping procedures?\u003c\/p\u003e\n\u003cp\u003eA: No. Electrical isolation of the subrack assembly is required prior to insertion or removal. Executing a live swap introduces transient noise variables that can disrupt backplane bus communication velocity licenses and cause processing faults.\u003c\/p\u003e\n\u003cp\u003eQ: How is the programming framework managed for this specific module?\u003c\/p\u003e\n\u003cp\u003eA: System application paths are configured using the three standard engineering configuration languages native to the ABB Advant Master environment, loading parameters directly into the integrated flash memory allocation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSlide the circuit card assembly smoothly into the assigned subrack alignment tracks until the rear-facing pin connectors mate completely with the backplane surface.\u003c\/li\u003e\n\u003cli\u003eSecure all integrated faceplate fasteners to establish low-resistance chassis ground bonding and lock the module against high-frequency industrial vibration components.\u003c\/li\u003e\n\u003cli\u003eMaintain a clearance perimeter of at least 100 mm between the enclosure subrack boundaries and any localized high-voltage AC current lines to suppress external inductive cross-talk.\u003c\/li\u003e\n\u003cli\u003eVerify that the internal grounding clips of the subrack are clear of non-conductive particulate accumulation prior to final module installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53054494933301,"sku":"DSBB 110A 57330001-Y","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DSBB110A2.png?v=1782898570","url":"https:\/\/www.5gplc.com\/products\/abb-dsbb-110a-57330001-y-advant-master-shield-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}