{"product_id":"abb-ci801-3bse022366r1-s800-i-o-profibus-dp-v1-communication-interface","title":"ABB CI801 3BSE022366R1 S800 I\/O PROFIBUS DP-V1 Communication Interface","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe \u003cstrong\u003eCI801\u003c\/strong\u003e module connects a PROFIBUS DP-V1 master to local S800 I\/O modules, supporting cyclic process data and acyclic parameter\/diagnostic communication. It handles up to 12 I\/O modules per cluster, providing high-speed, reliable, and flexible operation for water, chemical, and power applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eManufacturer:\u003c\/b\u003e\u003cspan class=\"\"\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number:\u003c\/b\u003e\u003cspan class=\"\"\u003e CI801\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eOrder Number:\u003c\/b\u003e\u003cspan class=\"\"\u003e 3BSE022366R1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series:\u003c\/b\u003e\u003cspan class=\"\"\u003e S800 I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication Protocol:\u003c\/b\u003e\u003cspan class=\"\"\u003e PROFIBUS DP-V1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eBaud Rate:\u003c\/b\u003e\u003cspan class=\"\"\u003e Auto-detecting up to 12 Mbit\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Voltage:\u003c\/b\u003e\u003cspan class=\"\"\u003e 24 V DC (19.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 – 30 V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Consumption:\u003c\/b\u003e\u003cspan class=\"\"\u003e 140 mA (Typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eMax I\/O Modules:\u003c\/b\u003e\u003cspan class=\"\"\u003e 12 units per cluster\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eIsolation:\u003c\/b\u003e\u003cspan class=\"\"\u003e Galvanic isolation to PROFIBUS side\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eDP-V1 Compatibility:\u003c\/b\u003e\u003cspan class=\"\"\u003e Supports advanced acyclic communication for remote device configuration and enhanced asset management diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eAutomatic Baud Rate Detection:\u003c\/b\u003e\u003cspan\u003e Simplifies commissioning by automatically synchronizing with the network speed of the PROFIBUS master.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eModular Scalability:\u003c\/b\u003e\u003cspan\u003e Provides a centralized management point for diverse digital and analog I\/O combinations within the S800 family.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eDiagnostic Monitoring:\u003c\/b\u003e\u003cspan\u003e Features comprehensive on-board status LEDs for power,\u003c\/span\u003e\u003cspan\u003e fault,\u003c\/span\u003e\u003cspan\u003e and network activity to streamline troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eIndustrial Hardening:\u003c\/b\u003e\u003cspan\u003e Designed to operate reliably in harsh electromagnetic environments with high resistance to vibration and temperature fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52108163121461,"sku":"CI801 3BSE022366R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI8013BSE022366R1.jpg?v=1767001617","url":"https:\/\/www.5gplc.com\/products\/abb-ci801-3bse022366r1-s800-i-o-profibus-dp-v1-communication-interface","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}