{"product_id":"abb-ci610-3bht300003r1-advant-master-bus-extender-module","title":"ABB CI610 3BHT300003R1 Advant Master Bus Extender Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB CI610 3BHT300003R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI610\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for I\/O bus expansion and signal routing within ABB Advant Master Process Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3BHT300003R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExchange Part Number\u003c\/td\u003e\n\u003ctd\u003e7650055-439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.195 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (D x H x W)\u003c\/td\u003e\n\u003ctd\u003e252 mm x 273 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Bus Extender Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB Advant Master Process Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe CI610 3BHT300003R1 extends the system IOB_A bus topology, transferring input\/output data signals between the primary control unit and auxiliary sub-racks. Internal bus driver logic ensures deterministic transmission speeds across expanded rack segments without inducing clock skew or backplane signal degradation. Onboard hardware architecture supports strict firmware flash compatibility across Advant Master system sub-assemblies, providing stable protocol execution and physical backplane interface synchronization during high-density I\/O scanning routines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary functional role of the CI610 module in an Advant Master system?\u003c\/p\u003e\n\u003cp\u003eA: The CI610 serves as an IOB_A bus extender, providing hardware-level signal extension from the main processing unit to additional I\/O sub-racks across the system backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Are external power supplies required to drive the internal logic of the CI610 unit?\u003c\/p\u003e\n\u003cp\u003eA: No. Operating power is drawn directly from the internal system backplane connections when properly seated in the assigned sub-rack slot.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CI610 module contain internal backup batteries?\u003c\/p\u003e\n\u003cp\u003eA: No. The physical hardware assembly contains zero internal batteries.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower Disconnection: Ensure the main power supply to the sub-rack enclosure is isolated before inserting or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eSlot Alignment: Guide the card along the chassis card guides carefully to ensure precise alignment of the backplane connector pins prior to applying seating force.\u003c\/li\u003e\n\u003cli\u003eCable Shielding: Connect all external bus extension cables using shielded twisted-pair wiring with ground drain wires terminated directly to the enclosure frame grounding point.\u003c\/li\u003e\n\u003cli\u003eFastening: Fully tighten the top and bottom front-panel retention screws to maintain solid mechanical grounding and prevent module dislodgement under vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53227713724725,"sku":"CI610 3BHT300003R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI6103BHT300003R1.png?v=1785398063","url":"https:\/\/www.5gplc.com\/products\/abb-ci610-3bht300003r1-advant-master-bus-extender-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}