{"product_id":"abb-ci502-pnio-1sap220700r0001-s500-profinet-io-interface-module","title":"ABB CI502-PNIO 1SAP220700R0001 S500 PROFINET IO Interface Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI502-PNIO (1SAP220700R0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance PROFINET IO RT (Real-Time) device within the S500 distributed automation platform. This interface module bridges the gap between decentralized field signals and the master controller, providing a hybrid mix of 8 digital inputs, 8 digital outputs, and 8 configurable I\/O channels. It manages discrete signals across an Industrial Ethernet backbone, ensuring millisecond-level synchronization for automated production lines. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your network maintains factory-certified communication integrity.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe CI502-PNIO utilizes a versatile hardware architecture to manage high-density discrete signals:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePROFINET IO RT (Real-Time)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 x Industrial Ethernet (RJ45)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels (24V DC, 5mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels (Transistor, 24V DC, 0.5A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable I\/Os:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels (Selectable DI or DO, 0.5A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Delay Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable 0.1 ms to 32 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (Range: 20.4 to 28.8 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e67.5 mm (W) x 76 mm (H) x 62 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.133 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Port Ethernet Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated 2-port Industrial Ethernet switch supports line and ring topologies. This allows for daisy-chaining multiple S500 clusters, which significantly reduces the total cabling cost and simplifies the network layout in large-scale installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible I\/O Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8 configurable DI\/DO channels allow for precise hardware customization. Engineers adapt the module to varying field requirements on-the-fly, reducing the need for multiple specialized spare parts and optimizing cabinet density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Signal Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable input delay times down to 0.1 ms ensure the module captures rapid signal pulses. This capability proves essential for high-speed packaging, sorting, and positioning tasks where standard I\/O latency creates process bottlenecks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Short-Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transistor outputs provide 0.5A current and include integrated protection against short circuits and overloads. This hardware-level safety prevents damage to the module during field wiring errors or actuator failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving S500 Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a width of only 67.5 mm, the CI502-PNIO maximizes rail space in decentralized control boxes. Its compact design facilitates installation in narrow enclosures or machine-mounted panels without restricting necessary airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CI502-PNIO require a specific Terminal Base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must install the CI502-PNIO on a compatible ABB Terminal Base (such as the TU507 or TU508). The terminal base provides the physical wiring connections and defines the local I\/O bus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module with third-party PROFINET Masters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CI502-PNIO complies with standard PROFINET IO RT device profiles. It integrates seamlessly with any PLC or DCS master that supports GSDML file imports, though it delivers the tightest integration within the ABB AC500 ecosystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle a loss of network communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can configure the output behavior (Safe State) through the engineering software. In the event of a PROFINET bus failure, the outputs can be programmed to hold their last value or switch to a predefined \"Off\" state to ensure process safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"8 Configurable I\/Os\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis feature provides ultimate flexibility. If your application requires 12 inputs and 12 outputs, you can configure 4 of the \"Configurable\" channels as DI and 4 as DO. This eliminates the cost and space required for a second I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52507091697973,"sku":"CI502-PNIO 1SAP220700R0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI502-PNIO1SAP220700R0001.jpg?v=1774854442","url":"https:\/\/www.5gplc.com\/products\/abb-ci502-pnio-1sap220700r0001-s500-profinet-io-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}