{"product_id":"abb-ci-741f-3bdh000396r0005-profibus-slave-communication-interface","title":"ABB CI 741F 3BDH000396R0005 PROFIBUS Slave Communication Interface","description":"\u003cp\u003eThe \u003cstrong\u003eABB CI741F 3BDH000396R0005\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI741F\u003c\/strong\u003e PROFIBUS Slave Communication Interface, operates as a dedicated hardware component for fieldbus data translation and multi-channel signal processing within Freelance AC 700F system architectures. The unit integrates a PROFIBUS DP slave port alongside 8 digital inputs, 8 digital outputs, 4 analog inputs, and 2 analog outputs for direct I\/O signal acquisition.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI741F 3BDH000396R0005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGlobal Manufacturing Facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.158 kg (158 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e67.5 mm x 62 mm x 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Operating Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W typical (24 VDC 1-wire: 100 W max total load capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003e1 x PROFIBUS DP Slave (Sub-D connector plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Channels\u003c\/td\u003e\n\u003ctd\u003e8 DI (24 VDC), 8 DO (24 VDC \/ 0.5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Channels\u003c\/td\u003e\n\u003ctd\u003e4 AI (+-10 V, 0\/4-20 mA, RTD), 2 AO (+-10 V, 0\/4-20 mA), 12-Bit + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Unit Base\u003c\/td\u003e\n\u003ctd\u003eCompatible with TU709F \/ TU710F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe CI741F module establishes deterministic cyclic communication over PROFIBUS DP network infrastructures while maintaining backplane bus communication velocity across attached S700 I\/O clusters. Its multi-signal density combines digital discrete logic and 12-bit analog loops into a single chassis footprint, optimizing cabinet I\/O density scaling without auxiliary expanders. The module maintains full firmware flash compatibility, allowing seamless node address configuration and protocol synchronization when docked onto TU709F or TU710F terminal units.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CI741F communication interface support hot-swap insertion during operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The CI741F does not support hot-swapping; power to the terminal unit base must be disconnected prior to removing or installing the module.\u003c\/p\u003e\n\u003cp\u003eQ: Which terminal unit bases are compatible with the CI741F module?\u003c\/p\u003e\n\u003cp\u003eA: The CI741F installs directly onto the ABB TU709F or TU710F terminal unit mounting bases.\u003c\/p\u003e\n\u003cp\u003eQ: What signal types are supported on the integrated analog channels?\u003c\/p\u003e\n\u003cp\u003eA: Analog inputs support +-10 V, 0\/4-20 mA current loops, and RTD temperature sensors. Analog outputs provide configurable +-10 V or 0\/4-20 mA control signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these technical procedures during panel installation and field wiring:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTerminal Base Docking: Align the rear connector pins of the CI741F with the TU709F or TU710F terminal unit interface, pressing straight in until the locking side tabs engage.\u003c\/li\u003e\n\u003cli\u003eGround \u0026amp; Shielding: Connect the PROFIBUS DP cable braid to the metallic shield clamp on the Sub-D connector shell to establish continuous low-impedance earthing.\u003c\/li\u003e\n\u003cli\u003eField Bus Connection: Fasten the 9-pin Sub-D PROFIBUS cable plug onto the module port and secure the mounting thumb screws.\u003c\/li\u003e\n\u003cli\u003eSignal Cable Separation: Route low-level analog input cables and RTD wires in dedicated wire ducts isolated from high-voltage AC lines to eliminate signal interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53434347323701,"sku":"CI 741F 3BDH000396R0005","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI741F3BDH000396R0005.png?v=1788161618","url":"https:\/\/www.5gplc.com\/products\/abb-ci-741f-3bdh000396r0005-profibus-slave-communication-interface","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}