{"product_id":"abb-cb801-3bse042245r1-profibus-dp-communication-module","title":"ABB CB801 3BSE042245R1 PROFIBUS DP Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB CB801 3BSE042245R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCB801\u003c\/strong\u003e PROFIBUS DP Communication Module, operates as a dedicated hardware component for fieldbus data exchange within Panel 800 control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCB801 (3BSE042245R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e121.5 mm x 49.5 mm x 153 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eVaries based on fieldbus transceiver load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 serial hardware connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Backplane and System Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe CB801 expansion module establishes cyclic slave data exchange across PROFIBUS DP deterministic networks at baud rates up to 12 Mbps. Interfacing via an RS-485 serial architecture, the internal communication logic coordinates cyclic I\/O data frames with minimal backplane latency.\u003c\/p\u003e\n\u003cp\u003eThe hardware architecture provides galvanic isolation along the fieldbus interface to prevent ground potential loops and suppress transient surge coupling. Full firmware flash compatibility ensures seamless integration with Panel 800 operator hardware without interrupting local backplane bus communication velocity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CB801 module automatically match the PROFIBUS DP master baud rate?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the onboard PROFIBUS controller performs automatic baud rate detection from 9.6 kbps up to 12 Mbps upon network initialization.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CB801 module be installed while the host Panel 800 terminal remains powered?\u003c\/p\u003e\n\u003cp\u003eA: No, the host terminal must be completely powered down prior to inserting or removing the CB801 expansion module from the interface bay.\u003c\/p\u003e\n\u003cp\u003eQ: What physical bus medium is required to connect the CB801 to the fieldbus network?\u003c\/p\u003e\n\u003cp\u003eA: Connections must be made using standard shielded twisted-pair cable complying with PROFIBUS DP RS-485 physical layer specifications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize all primary power supplies to the Panel 800 terminal before inserting the module into the expansion slot.\u003c\/li\u003e\n\u003cli\u003eAttach a grounded wrist strap to prevent electrostatic discharge when handling the internal module PCB and connector pins.\u003c\/li\u003e\n\u003cli\u003eSlide the CB801 module straight into the dedicated slot until the multi-pin backplane connector seats completely.\u003c\/li\u003e\n\u003cli\u003eFasten all mechanical retaining screws to ensure proper grounding continuity through the chassis enclosure.\u003c\/li\u003e\n\u003cli\u003eRoute PROFIBUS DP cables away from high-voltage AC lines and VFD output wiring to maintain communication signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53265253466421,"sku":"CB801 3BSE042245R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CB8013BSE042245R1.png?v=1786350403","url":"https:\/\/www.5gplc.com\/products\/abb-cb801-3bse042245r1-profibus-dp-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}