{"product_id":"abb-bc810k02-3bse031155r1-system-800xa-interconnection-communication-module","title":"ABB BC810K02 3BSE031155R1 System 800xA Interconnection Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB BC810K02 3BSE031155R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBC810K02\u003c\/strong\u003e Interconnection Communication Module, operates as a dedicated hardware component for segmenting and extending the CEX-Bus protocol within System 800xA AC 800M platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBC810K02 3BSE031155R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (3.31 lbs) including base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e59 mm x 185 mm x 127.5 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA typical (70 mA max) at 24 VDC; 1.2 W power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2 VDC to 30 VDC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eBaseplate (TP857) plus power supply\/logic board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy \u0026amp; Integrity\u003c\/td\u003e\n\u003ctd\u003eSupported (Redundant and High Integrity configurations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Support\u003c\/td\u003e\n\u003ctd\u003eYes (Online replacement supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible CPUs\u003c\/td\u003e\n\u003ctd\u003ePM857, PM861A, PM862, PM863, PM864A, PM865, PM866, PM866A, PM867, PM891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; CEX-Bus Segmentation\u003c\/h3\u003e\n\u003cp\u003eThe BC810K02 divides the CEX-Bus into isolated electrical segments to increase system fault tolerance and maintain maximum backplane bus communication velocity across expanding I\/O network topologies. Featuring onboard power voting diodes, a 3.3 VDC step-down converter, and CEX-Bus driver logic, the unit isolates signal faults to individual segments. Onboard firmware flash compatibility enables continuous data sync between primary and backup AC 800M processor pairs, permitting online replacement of CPU baseplates without interrupting active CEX-Bus communication streams.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What happens to active network communication if a BC810K02 module needs to be replaced?\u003c\/p\u003e\n\u003cp\u003eA: Replacing a BC810K02 module halts data traffic specifically on its connected CEX-Bus segment, while other isolated CEX segments in a redundant system maintain uninterrupted operation.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for the BC810K02 during online operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the BC810K02 supports hot-swap replacement and allows online replacement of the CPU baseplate in a fully redundant CPU pair configuration without disturbing overall CEX traffic.\u003c\/p\u003e\n\u003cp\u003eQ: What supply voltage range does the module accept, and how is it protected against supply faults?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts a nominal supply voltage of 24 VDC within a 19.2 VDC to 30 VDC tolerance range. The TP857 baseplate integrates an external power voting diode and internal fuse protection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TP857 baseplate directly onto the cabinet DIN-rail, ensuring the housing metal contacts make direct metal-to-metal grounding contact.\u003c\/li\u003e\n\u003cli\u003eWire external 24 VDC redundant power lines to the L+ and L- terminal designations on the baseplate.\u003c\/li\u003e\n\u003cli\u003eAlign the BC810 power supply\/logic board with the baseplate connectors and press firmly into position until the module latches engage.\u003c\/li\u003e\n\u003cli\u003eAttach the CEX-Bus interconnection cable between the module connector and the adjacent CPU baseplate or CEX segment extension.\u003c\/li\u003e\n\u003cli\u003eVerify power LED status and confirm that the CEX segment data traffic initializes without bus degradation before securing panel doors.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53218387591477,"sku":"BC810K02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BC810K02.png?v=1785136462","url":"https:\/\/www.5gplc.com\/products\/abb-bc810k02-3bse031155r1-system-800xa-interconnection-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}