{"product_id":"abb-bailey-tps02-turbine-protection-system-slave-module","title":"ABB Bailey TPS02 Turbine Protection System Slave Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"citation-406 citation-end-406\"\u003eThe ABB \u003cstrong\u003eTPS02\u003c\/strong\u003e is a specialized safety interface module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"citation-405 citation-end-405\"\u003eIt is primarily utilized in power generation for critical turbine protection and overspeed monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module provides a dedicated link between the system’s logic and the turbine trip circuitry,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring rapid and deterministic execution of emergency shutdown commands.\u003c\/span\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"citation-404 citation-end-404 animating\"\u003eBy monitoring essential process parameters and mechanical states, the TPS02 helps prevent catastrophic equipment failure and maintains the integrity of the steam or gas turbine control loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e TPS02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cspan class=\"citation-403 animating\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"animating\"\u003e\u003cspan class=\"citation-403\"\u003eProduct Series\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-403 citation-end-403\"\u003e: INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cspan class=\"citation-402 animating\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"animating\"\u003e\u003cspan class=\"citation-402\"\u003eModule Type\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-402 citation-end-402\"\u003e: Turbine Protection Slave\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Redundant trip inputs and speed sensor signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Emergency trip relay drivers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single slot in standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Supply\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (backplane powered)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cspan class=\"citation-401 animating\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"animating\"\u003e\u003cspan class=\"citation-401\"\u003eHigh-Speed Trip Logic\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-401 citation-end-401\"\u003e: Designed for low-latency signal processing to meet stringent turbine safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundancy Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Compatible with redundant system architectures to ensure protection remains active even during single-component failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Performance\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Operates on a dedicated slave bus to avoid network congestion and ensure consistent response times.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eSafety Isolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features electrical separation between sensitive control logic and high-power turbine trip solenoids.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\" class=\"\"\u003eReal-Time Diagnostics\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Includes internal hardware verification routines that report status and fault conditions to the master controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095731138869,"sku":"TPS02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TPS02__1.jpg?v=1766650692","url":"https:\/\/www.5gplc.com\/products\/abb-bailey-tps02-turbine-protection-system-slave-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}