{"product_id":"abb-bailey-imcp02-infi-net-multibus-communication-processor-module","title":"ABB Bailey IMCP02 Infi-Net Multibus Communication Processor Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e IMCP02 \u003c\/strong\u003eis a high-performance communication processor module designed to facilitate complex data exchange within the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module acts as a sophisticated gateway between the proprietary high-speed Infi-Net plant loop and Multibus-based hardware architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its primary function is to manage the translation and routing of process data,\u003c\/span\u003e\u003cspan class=\"\"\u003e control commands,\u003c\/span\u003e\u003cspan class=\"\"\u003e and system diagnostics across disparate bus structures.\u003c\/span\u003e\u003cspan class=\"\"\u003e By utilizing dedicated on-board processing power,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMCP02 ensures that high-volume network traffic does not interfere with the deterministic execution of critical control loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it indispensable for large-scale,\u003c\/span\u003e\u003cspan class=\"\"\u003e networked industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMCP02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network Communication Processor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eArchitecture Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Infi-Net to Multibus Gateway\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eProtocol Handling\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Real-time asynchronous and synchronous data management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMemory Configuration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated RAM and ROM for protocol firmware and buffering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (provided via system backplane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eSlot Requirement\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single slot occupancy in standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eMultibus Integration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Specifically engineered to link Infi-Net communication highways with Multibus-compliant hardware components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Data Transfer\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Employs advanced scheduling algorithms to ensure that time-critical process data receives priority during network transmission.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eAutonomous Processing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Reduces the overhead on main controller modules by independently managing network layer protocols and error correction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eSystem-Wide Connectivity\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Enables transparent access to data points located on different segments of the plant loop for improved supervisory control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eComprehensive Self-Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously audits hardware integrity and communication link status,\u003c\/span\u003e\u003cspan\u003e providing immediate fault reporting to the operator interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Reliability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built to withstand the rigorous electrical and thermal demands of power generation and heavy manufacturing facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095845564725,"sku":"IIMCP02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IIMCP02.jpg?v=1766656849","url":"https:\/\/www.5gplc.com\/products\/abb-bailey-imcp02-infi-net-multibus-communication-processor-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}