{"product_id":"abb-ax561-1tne968902r1301-s500-analog-i-o-module","title":"ABB AX561 1TNE968902R1301 S500 Analog I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB AX561 1TNE968902R1301\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAX561\u003c\/strong\u003e Analog Input\/Output Module, operates as a dedicated hardware component for analog signal processing and field device control within ABB S500 and AC500-eCo I\/O platforms. The module manages 4 analog inputs and 2 analog outputs configured for voltage or current loops using a 1-wire connection scheme. It converts incoming analog field variables into 12-bit digital values while driving proportional control signals to field actuators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAX561 1TNE968902R1301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.122 kg (0.27 lbs) net \/ 0.225 kg gross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34 mm x 135 mm x 74 mm (1.34 in x 5.31 in x 2.91 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Storage: -40 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via internal I\/O bus and 24 VDC process power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (Voltage U, Current I, 12-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels (Voltage U, Current I, 12-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Interface\u003c\/td\u003e\n\u003ctd\u003e1-wire connection, pluggable terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic I\/O Density Scaling and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe AX561 module scales analog I\/O density within compact DIN-rail mounting footprints, executing continuous signal updates across the S500 expansion bus. Integrated firmware flash compatibility across AC500-eCo CPU processors ensures automatic parameter assignment during rack initialization. High-velocity backplane communication prevents data transmission latencies, maintaining deterministic execution for 12-bit conversion cycles on both input acquisition and output command channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What resolution is provided on the analog channels of the AX561 module?\u003c\/p\u003e\n\u003cp\u003eA: Both the 4 analog inputs and the 2 analog outputs feature a 12-bit analog-to-digital \/ digital-to-analog signal conversion resolution.\u003c\/p\u003e\n\u003cp\u003eQ: Can the AX561 channels be hot-swapped while the CPU is executing logic?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the CPU terminal base and process voltage supply must be isolated prior to removing or seating the module to avoid bus communication faults and hardware damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the AX561 onto the S500\/AC500-eCo terminal base unit on a standard 35 mm DIN rail, pushing until the locking latch firmly clicks.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring for voltage (U) or current (I) loops is de-energized before inserting conductors into the pluggable terminal blocks.\u003c\/li\u003e\n\u003cli\u003eKeep analog signal cables physically separated from high-voltage AC lines and switching inductive loads by a minimum distance of 200 mm.\u003c\/li\u003e\n\u003cli\u003eGround all shielded twisted-pair cables at a single point near the panel entry point to eliminate potential ground loop interference across 12-bit resolution channels.\u003c\/li\u003e\n\u003cli\u003eConfirm that the terminal block screws are torqued to 0.5 Nm to maintain secure mechanical and electrical contact.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53224469233973,"sku":"AX561 1TNE968902R1301","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AX5611TNE968902R1301.png?v=1785304278","url":"https:\/\/www.5gplc.com\/products\/abb-ax561-1tne968902r1301-s500-analog-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}