{"product_id":"abb-ai561-1tne968902r1101-s500-eco-analog-input-module","title":"ABB AI561 1TNE968902R1101 S500-eCo Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB AI561 1TNE968902R1101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAI561\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel analog signal acquisition within S500-eCo distributed I\/O systems. The module maps physical transmitter signals to internal CPU registers using a 1-wire connection typology to interface voltage and current field circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg net \/ 0.16 kg gross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34 mm x 74 mm x 135 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via peripheral bus link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eVoltage (U), Current (I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003ePluggable terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eHousing IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Networks \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates data packets directly into remote sub-stations communicating over Profinet \/ EtherNet\/IP deterministic networks. High I\/O density scaling allows synchronous internal processing of current loop and voltage signals through individual register mappings. Backplane bus communication velocity licenses dictate the cyclic timing parameter, while rigorous internal components enforce strict firmware flash compatibility matching with the designated host CPU architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the terminal block system for the AI561 removable under field operational conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module features pluggable connection blocks that permit electrical detachment for terminal servicing without disconnecting physical loop wires from screw terminals.\u003c\/p\u003e\n\u003cp\u003eQ: Can voltage and current inputs be wired to different channels simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 4 analog input channels accept U or I configuration selections parameterised through the local engineering environment, provided wiring aligns with specified terminal schematics.\u003c\/p\u003e\n\u003cp\u003eQ: Does this hardware configuration support hot-swap capabilities during CPU operation?\u003c\/p\u003e\n\u003cp\u003eA: No. S500-eCo modules require power interruption before component extraction or insertion to protect internal logic gates from backplane bus transit spikes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the assembly directly onto a standard 35 mm DIN rail ensuring proper physical locking alignment of the baseline chassis tabs.\u003c\/li\u003e\n\u003cli\u003eDirect physical separation of a minimum of 100 mm must be maintained between low-voltage signal cables and active AC power wiring.\u003c\/li\u003e\n\u003cli\u003eConnect all field transmitter shield braids to an isolated ground bus located within the common terminal enclosure to damp external high-frequency line interference.\u003c\/li\u003e\n\u003cli\u003eVerify proper wire gage insertion depths within the pluggable blocks before snapping components securely together to guarantee constant terminal continuity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53054363173173,"sku":"AI561 1TNE968902R1101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AI5611TNE968902R1101.png?v=1782895658","url":"https:\/\/www.5gplc.com\/products\/abb-ai561-1tne968902r1101-s500-eco-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}