{"product_id":"abb-560b0r01-1kgt036800r0002-binary-output-modules","title":"ABB 560B0R01 1KGT036800R0002 Binary Output Modules","description":"\u003cp\u003eThe \u003cstrong\u003eABB 560B0R01 1KGT036800R0002\u003c\/strong\u003e, also cataloged as the 560B0R01 Binary Output Module, operates as a dedicated hardware component for switching field discrete control signals within ABB RTU560 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e560B0R01 (1KGT036800R0002)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.202 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14 cm x 20.5 cm x 3.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e16 Single-Pole, Normally Open Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Grouping\u003c\/td\u003e\n\u003ctd\u003e2 Groups of 8 Channels with Common Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24-125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Capacity\u003c\/td\u003e\n\u003ctd\u003eContinuous 2 A per Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 560B0R01 binary output module establishes a high-density switching interface between the central processing unit and field actuation equipment. Integrated backplane bus communication velocity allows rapid response times for command execution over Profinet and EtherNet\/IP deterministic networks without introducing bus contention or signal latency. High channel integration supports scalable I\/O density within compact subracks, while onboard memory circuits support firmware flash compatibility across RTU system updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are the 16 relay channels isolated and grouped electrically?\u003c\/p\u003e\n\u003cp\u003eA: The 16 single-pole normally open relay outputs are divided into two distinct groups of eight channels, each sharing a common return line for group voltage isolation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 560B0R01 module be hot-swapped during active system rack operation?\u003c\/p\u003e\n\u003cp\u003eA: Module replacement requires de-energizing the field relay voltages and subrack power supply prior to insertion or removal to prevent electrical arcing and backplane pin damage.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum voltage rating for the output relay contacts?\u003c\/p\u003e\n\u003cp\u003eA: The relay contacts support a maximum switching voltage of 150 VDC, with an operating voltage range between 24 VDC and 125 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all external field loop voltages and system subrack power before installing or extracting the module.\u003c\/li\u003e\n\u003cli\u003eObserve group current limits by ensuring continuous current across each eight-channel group does not exceed 2 A.\u003c\/li\u003e\n\u003cli\u003eConnect external suppression diodes across inductive DC loads to mitigate voltage spikes during relay contact opening.\u003c\/li\u003e\n\u003cli\u003eEnsure proper chassis grounding via the DIN rail or panel mounting interface using short, low-impedance connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53254124339509,"sku":"560B0R01 1KGT036800R0002","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/560B0R011KGT036800R0002.png?v=1786009182","url":"https:\/\/www.5gplc.com\/products\/abb-560b0r01-1kgt036800r0002-binary-output-modules","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}