{"product_id":"abb-3bdh000022r1-ei813f-ethernet-modules","title":"ABB 3BDH000022R1 EI813F Ethernet Modules","description":"\u003cp\u003eThe \u003cstrong\u003eABB 3BDH000022R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eEI813F\u003c\/strong\u003e Ethernet Module, operates as a dedicated hardware component for deterministic 10BaseT network interfacing within Freelance AC 800F control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BDH000022R1 (EI813F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMalta (MT) \/ Germany (DE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard AC 800F fieldbus module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C (standard industrial enclosure rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via AC 800F base unit internal system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003e10BaseT Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Compatibility\u003c\/td\u003e\n\u003ctd\u003eAC 800F PM 802F, PM 803F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Requirement\u003c\/td\u003e\n\u003ctd\u003eDigiVis \/ Freelance V7.1SP2a or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Board Battery\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe EI813F module connects to the CPU backplane bus of the PM 802F or PM 803F controllers, converting internal process control tasks into 10BaseT Ethernet frame structures. Internal bus timing protocols enforce deterministic communication velocities between process controllers, engineering stations, and operator visualization nodes. firmware flash compatibility managed via Freelance software V7.1SP2a (or higher) guarantees system synchronization without frame collisions during process data exchange.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which CPU module platforms are compatible with the EI813F Ethernet module?\u003c\/p\u003e\n\u003cp\u003eA: The EI813F (3BDH000022R1) is designed specifically for connection to ABB Freelance AC 800F controller bases utilizing PM 802F or PM 803F central processing units.\u003c\/p\u003e\n\u003cp\u003eQ: Is an internal backup battery required for operation or network parameter retention?\u003c\/p\u003e\n\u003cp\u003eA: No, the module operates without an internal battery. Network configuration settings are maintained via non-volatile memory managed by the AC 800F system software.\u003c\/p\u003e\n\u003cp\u003eQ: What minimum software revision is required for module recognition?\u003c\/p\u003e\n\u003cp\u003eA: System firmware and configuration software must be at version V7.1SP2a or higher to ensure proper hardware driver initialization and communication setup.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the AC 800F controller rack prior to inserting or removing the EI813F module from the expansion slot.\u003c\/li\u003e\n\u003cli\u003eVerify that the CPU base unit is equipped with a compatible PM 802F or PM 803F processor module.\u003c\/li\u003e\n\u003cli\u003eAlign the module edge connector with the rack slot guide rails and press firmly until the locking tabs seat completely.\u003c\/li\u003e\n\u003cli\u003eConnect CAT5 (or higher) shielded twisted-pair (STP) cabling with standard RJ45 connectors to the 10BaseT port.\u003c\/li\u003e\n\u003cli\u003eGround the Ethernet cable shield to the industrial enclosure cable entry plate to minimize electromagnetic noise interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53211901591861,"sku":"EI813F 3BDH000022R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/EI813F3BDH000022R1.png?v=1784872593","url":"https:\/\/www.5gplc.com\/products\/abb-3bdh000022r1-ei813f-ethernet-modules","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}