{"product_id":"abb-1sap217000r0001-tu532-terminal-unit","title":"ABB 1SAP217000R0001 TU532 Terminal Unit","description":"\u003cp\u003eConfigured for physical field wiring termination and module interfacing in S500 I\/O systems, the \u003cstrong\u003eABB 1SAP217000R0001\u003c\/strong\u003e (\u003cstrong\u003eTU532\u003c\/strong\u003e Terminal Unit) provides direct physical\/electrical execution. The hardware connects 230 VAC discrete signals and relay expansion modules to the system backplane through spring-terminal connection points.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1SAP217000R0001 (TU532)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ Standard ABB Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.164 kg (Net) \/ 0.194 kg (Gross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e67.5 mm x 135 mm x 28 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Storage: -40 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Backplane Route (24 VDC Supply Voltage Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eSpring Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd\u003e230 VAC Inputs \/ Outputs \u0026amp; Relay Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences \u0026amp; Power Routing\u003c\/h3\u003e\n\u003cp\u003eThe base unit integrates passive bus lines that interface S500 I\/O modules directly with the controller backplane. Embedded conductor paths support backplane bus communication velocity Licences required for real-time deterministic cyclic data transfer across the local expansion cluster. Galvanic routing paths isolate high-voltage 230 VAC switching potentials on the field terminal side from internal 24 VDC backplane logic circuitry, maintaining noise immunity and structural signal integrity during fast transient events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can I replace an S500 I\/O module mounted on the TU532 without disconnecting field wiring?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The TU532 terminal unit retains all spring-terminal field connections on its base frame, allowing plugged I\/O modules to be unlatched and swapped without disturbing field wiring looms.\u003c\/p\u003e\n\u003cp\u003eQ: What conductor wire cross-sections are supported by the spring terminals?\u003c\/p\u003e\n\u003cp\u003eA: The spring-clamp terminals accept standard solid or ferruled flexible copper conductors up to 2.5 mm sq for AC power and field signal routing.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TU532 carry an IP protection rating for wet environments?\u003c\/p\u003e\n\u003cp\u003eA: The unit carries an IP20 rating and must be installed inside an enclosure providing adequate ingress protection against conductive dust, moisture, and debris.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the terminal unit onto a standard 35 mm DIN rail by snapping the rear locking mechanism firmly into place before inserting I\/O modules.\u003c\/li\u003e\n\u003cli\u003eStrip field conductor insulation to specified length (typically 9 to 10 mm) before inserting into spring clamp terminals using a flat-head screwdriver.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the DIN rail to cabinet PE bus to establish a low-impedance ground path for high-voltage isolation circuits.\u003c\/li\u003e\n\u003cli\u003eVerify isolation of 230 VAC field supply lines prior to wiring terminal connections or inserting\/removing adjacent expansion hardware.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53235458048309,"sku":"TU532 1SAP217000R0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TU532.png?v=1785469880","url":"https:\/\/www.5gplc.com\/products\/abb-1sap217000r0001-tu532-terminal-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}