{"product_id":"aam50-yokogawa-current-output-module-for-centum-cs-3000","title":"AAM50 | Yokogawa Current Output Module for CENTUM CS 3000","description":"\u003cp\u003eThe Yokogawa \u003cstrong\u003eAAM50\u003c\/strong\u003e is a high-performance analog output module engineered for the CENTUM CS 3000 distributed control system. It serves as the critical interface for transmitting control commands from the processor to field actuators, such as control valves, dampers, and variable speed drives. The AAM50 addresses the need for precise, stable signal transmission in noisy industrial environments by providing 8 independent current output channels. Its robust design ensures that the 4 to 20 mA DC signals driving your final control elements remain accurate and free from the interference that can compromise process stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AAM50 is built to deliver reliable analog control with a focus on channel isolation and compact integration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCurrent Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eAAM50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e8 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eChannel-to-Channel (Independent Isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eApprox. 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-20 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e130 x 30 x 100 mm (5.1 x 1.2 x 3.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.4 kg (0.88 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Code Interpretation\u003c\/h3\u003e\n\u003cp\u003eFor Yokogawa modules, the suffix code is critical as it defines the specific communication protocol support and physical interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAAM50\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAAM50-AXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA (Base Model):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe standard AAM50 typically supports standard analog output signals (4-20 mA).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix Variations (e.g., AAM50B):\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-B\u003c\/strong\u003e: Often denotes support for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBRAIN protocol\u003c\/strong\u003e, allowing for digital communication and configuration of intelligent field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S1 \/ -S2\u003c\/strong\u003e: These suffixes usually indicate specific hardware revisions or regional specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003eNote: Always verify the specific suffix on the module label to ensure it meets the communication protocol requirements of your field devices (Standard Analog vs. BRAIN Protocol).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure reliable control and signal integrity, follow these installation practices:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AAM50 is designed to mount into specific I\/O carrier boxes (such as the AAM series carriers). Ensure the module is fully inserted into the slot and the locking mechanism is engaged to secure the connection to the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Advantage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e. This is a critical feature that prevents ground loops between different field devices. You can connect actuators with different common-mode voltage potentials without risk of interference or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded twisted-pair cables for the 4-20 mA loops. Connect the shield to the ground terminal at the cabinet end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the external 24 VDC power supply is stable and capable of handling the aggregate current draw of all active output channels (approx. 5 W consumption).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the AAM50?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AAM50 converts digital control signals from the CENTUM system into analog 4-20 mA current signals to drive field devices like control valves and actuators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AAM50 provide channel isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the AAM50 features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 isolated current output channels\u003c\/strong\u003e. Each channel is independently isolated, which prevents ground loops and signal interference between connected devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the AAM50 compatible with CENTUM VP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AAM50 is primarily designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. While some hardware is backward compatible, you should verify the specific I\/O bus compatibility if attempting to use it in a CENTUM VP system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between AAM50 and AAM50B?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAM50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used for standard analog current output. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAM50B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion typically supports the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBRAIN protocol\u003c\/strong\u003e, enabling digital communication with intelligent Yokogawa devices.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52522886431029,"sku":"AAM50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AAM11_3e50c952-3e33-43b0-b686-f580ac12dda0.jpg?v=1775039376","url":"https:\/\/www.5gplc.com\/products\/aam50-yokogawa-current-output-module-for-centum-cs-3000","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}