{"product_id":"a6120-emerson-ams-6500-shaft-vibration-and-speed-monitor","title":"A6120 | Emerson | AMS 6500 Shaft Vibration and Speed Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson A6120\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision dual-channel monitor within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMS 6500 Protection System\u003c\/strong\u003e. It captures critical dynamic data, specifically shaft vibration and rotational speed, to protect high-speed turbines and compressors. This module acts as the primary interface between eddy current proximity probes and the rack's logic layer. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical assets operate within safety limits without the risks associated with used or refurbished hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe A6120 utilizes high-resolution analog-to-digital conversion to maintain signal integrity in harsh electromagnetic environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMS 6500 Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Independent dynamic channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy current proximity probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Hz to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 5 W (Backplane powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 V to +24 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-system electrical isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Signal Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated filtering and amplification circuits strip away industrial interference, delivering clean vibration profiles even in heavy EMI environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamline Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hot-swappable design allows technicians to replace modules without powering down the entire AMS 6500 rack, significantly reducing scheduled downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Asset Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable alert and danger thresholds trigger immediate protective actions. The module processes signals at a high resolution to detect subtle shaft misalignments before they lead to catastrophic bearing failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module docks directly into the standard AMS 6500 rack slot. It communicates via the internal backplane, removing the need for complex external wiring between monitoring cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the A6120 arrive in original factory packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. We provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmerson A6120 modules. Each unit ships in its original factory seal with a verified serial number to ensure authenticity and full manufacturer performance standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle both vibration and speed simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The A6120 features two independent dynamic channels. You can configure these channels to monitor shaft vibration via proximity probes or track rotational speed. The high-frequency range (up to 10 kHz) ensures accurate pulse counting for overspeed protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the primary installation requirements for the A6120?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module requires a standard AMS 6500 rack slot. During installation, ensure the rack provides adequate passive airflow as the A6120 relies on the system's cooling method to maintain its -20°C to +65°C operating range. Use the AMS system software tools for threshold configuration and calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module to replace an older vibration card in an existing AMS 6500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The A6120 maintains backward compatibility with standard AMS 6500 backplanes. However, we recommend verifying your current software configuration version to ensure the system recognizes the high-resolution features of the new module.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52546278916405,"sku":"A6120","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/A61102_ee6bf634-5d9c-4a2d-b2dd-1d7b408b98f6.jpg?v=1775617918","url":"https:\/\/www.5gplc.com\/products\/a6120-emerson-ams-6500-shaft-vibration-and-speed-monitor","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}