{"product_id":"900u02-0100-honeywell-controledge-hc900-universal-analog-input-module","title":"900U02-0100 | Honeywell | ControlEdge HC900 Universal Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 900U02-0100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the high-performance tier of universal analog input (AI) technology within the ControlEdge HC900 platform. This module eliminates the need for multiple specialized cards by processing a diverse range of signal types, including Thermocouples, RTDs, Voltages, and Milliamps. It functions as the primary sensory interface for complex PID loops and data acquisition tasks in demanding process industries. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original factory condition\u003c\/strong\u003e, ensuring your system maintains peak measurement accuracy and long-term stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 900U02-0100 integrates high-resolution conversion circuitry with a compact mechanical footprint:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Analog Input (8-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eT\/C, RTD, 0-10V, 0-20mA, 4-20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit A\/D Converter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10cm x 5cm x 11cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg (1.43 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Channel-to-Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnified Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 900U02-0100 handles almost any analog sensor type on a per-channel basis. This versatility reduces your spare parts inventory by 60%, as one module type replaces several dedicated temperature or voltage cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced EMI\/RFI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module’s internal circuitry filters out high-frequency industrial noise. This ensures rock-solid signal stability even when you install the I\/O rack near Variable Frequency Drives (VFDs) or heavy switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach input channel features robust isolation from the controller backplane. This prevents ground loops and safeguards your central CPU from field-side electrical transients, significantly increasing the total system lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Thermal Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor temperature-critical applications, the module incorporates an integrated Cold Junction Compensation (CJC) mechanism. This maintains thermocouple accuracy across the full operating temperature range of the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 900U02-0100 require external signal conditioners for Thermocouples?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The module accepts Thermocouple leads directly. The internal hardware handles the linearization and CJC, sending the final temperature value straight to the HC900 processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix different signal types on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. You configure each of the 8 channels independently via the HC900 Designer software. For example, you can assign Channel 1 to a Type K Thermocouple while setting Channel 2 to a 4-20mA pressure transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I ensure the best accuracy for RTD measurements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 900U02-0100 supports 3-wire RTD configurations to compensate for lead-wire resistance. Always use high-quality shielded twisted pair cabling and ensure the terminal block connections remain tight to prevent resistance-induced errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this 900U02-0100 unit a used or \"refurbished\" module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. We guarantee this is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal Honeywell product. New modules are essential for analog paths to ensure the internal capacitors and reference voltages remain within factory-calibrated tolerances.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52866472313141,"sku":"900U02-0100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900U02-0100.png?v=1778571100","url":"https:\/\/www.5gplc.com\/products\/900u02-0100-honeywell-controledge-hc900-universal-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}