{"product_id":"900h02-0001-honeywell-digital-output-module","title":"900H02-0001 Honeywell Digital Output Module","description":"\u003cp\u003eConfigured for high-density discrete signal switching in HC900 control networks, the \u003cstrong\u003eHoneywell 900H02-0001\u003c\/strong\u003e (\u003cstrong\u003e900H02\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. The module manages external 24 VDC to 32 VDC loads via solid-state switching channels based on internal processor states.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900H02-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Module Type\u003c\/td\u003e\n\u003ctd\u003eHC900 \/ Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 lbs (0.16 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard HC900 chassis slot allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e426 mA maximum at 5 VDC internal backplane draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Range\u003c\/td\u003e\n\u003ctd\u003e32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Rating\u003c\/td\u003e\n\u003ctd\u003e1 A per channel \/ 8 A maximum per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Integrity\u003c\/h3\u003e\n\u003cp\u003eThe electrical design of the 900H02-0001 features rigorous galvanic channel-to-channel isolation zones alongside optical barrier separation between the internal logic circuitry and the 32 VDC field side routing. This physical configuration prevents common-mode noise propagation and ground loop currents from injecting electrical anomalies into neighboring 4-20 mA HART loop protocol lines or low-voltage analog inputs positioned on the same rack backplane. Inductive transient suppression networks are paired with the switching elements to filter out high-voltage feedback spikes from collapsing magnetic fields in solenoid coils.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 900H02-0001 module support live hot-swap insertion and extraction during active rack processing?\u003c\/p\u003e\n\u003cp\u003eA: No. Removing or inserting the module while the HC900 backplane is energized can induce transient electrical noise on the shared bus, causing internal communication faults or unsafe dropouts on adjacent channels.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current load limitations when deploying multiple 900H02-0001 modules in a single rack assembly?\u003c\/p\u003e\n\u003cp\u003eA: Each module pulls a maximum of 426 mA from the 5 VDC logic supply. Total rack consumption must be calculated against the rating of the primary power supply module to prevent overcurrent trip conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Seating\u003c\/strong\u003e: Align the module circuit board with the upper and lower plastic guides within the designated slot. Push the assembly straight into the backplane until the interface pins lock securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Routing Constraints\u003c\/strong\u003e: Separate all VDC discrete output loops from high-voltage alternate current paths and variable frequency drive motor leads within the containment trays to prevent cross-talk coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Fuse Allocation\u003c\/strong\u003e: Install high-speed current limiting fuses on the field supply side for each block of channels to prevent continuous module overloads from breaching the 8 A absolute physical limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield and Ground Continuity\u003c\/strong\u003e: Terminate external cable drain wires and internal reference ground paths at the unified enclosure grounding bar before energizing the module input channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53136833347893,"sku":"900H02-0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900H02-0001.png?v=1784110224","url":"https:\/\/www.5gplc.com\/products\/900h02-0001-honeywell-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}