{"product_id":"900cp1-0200-honeywell-controledge-hc900-control-processor-module","title":"900CP1-0200 | Honeywell  ControlEdge HC900 Control Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 900CP1-0200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-performance brain of the ControlEdge HC900 automation platform. This industrial-grade processor executes complex logic, manages high-speed PID loops, and coordinates communication across the entire I\/O network. Designed for mission-critical applications, it supports dual-redundant configurations to eliminate single points of failure in process environments. We supply this module in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original condition\u003c\/strong\u003e, ensuring your facility benefits from the latest hardware revisions and a full 12-month warranty.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 900CP1-0200 integrates robust processing power with versatile network compatibility:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed industrial-grade CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLarge RAM with Non-volatile Flash storage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Dual-Redundant Controller configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetworking\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTE (Fault Tolerant Ethernet), I\/O Link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus, OPC, Ethernet\/IP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries C I\/O Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e137 x 38.1 x 137.16 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight \/ Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 kg \/ Made in USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Downtime Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 900CP1-0200 supports full hot-swap capability within the Series C chassis. This allows maintenance teams to replace a processor module while the system remains energized, significantly reducing MTTR (Mean Time To Repair) without interrupting active processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Tolerant Ethernet (FTE) Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module utilizes Honeywell’s proprietary FTE technology to provide rapid network recovery. It maintains communication even during a cable break or switch failure, solving the common industrial pain point of network-induced process trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe native support for Modbus, OPC, and Ethernet\/IP streamlines the integration of third-party devices. This eliminates the need for expensive protocol converters and simplifies data exchange with SCADA and HMI layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged USA-Made Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to withstand 95% non-condensing humidity and high-vibration environments, the 900CP1-0200 thrives in harsh manufacturing sites. The high-speed CPU manages large-scale I\/O counts without compromising scan cycle consistency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 900CP1-0200 require a separate memory card for logic storage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The module includes large internal non-volatile storage. It retains the user program and configuration data without the need for an external card, though you should always maintain a digital backup via the HC900 Designer software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the dual-redundancy feature function during a CPU failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn a redundant setup, the secondary 900CP1-0200 tracks the primary’s state in real-time. If the primary processor fails, the secondary module assumes control within milliseconds, ensuring the process variables remain stable and the plant stays online.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I install this module in an older HC900 chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module requires a Series C chassis to function correctly. Always verify your backplane version and firmware compatibility in the HC900 hardware manual before upgrading older legacy systems to the 900CP1-0200.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this unit a refurbished or \"new-surplus\" item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe guarantee this 900CP1-0200 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original. It arrives in factory packaging with all original certifications, ensuring your system operates according to the manufacturer's exact performance and safety specifications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52866254733621,"sku":"900CP1-0200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900CP1-0200.png?v=1778569544","url":"https:\/\/www.5gplc.com\/products\/900cp1-0200-honeywell-controledge-hc900-control-processor-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}