{"product_id":"8237-1600-protech-gii-overspeed-detection-device-woodward","title":"8237-1600 ProTech-GII Overspeed Detection Device | Woodward","description":"\u003cp\u003eConfigured for overspeed detection in turbine control systems, the \u003cstrong\u003eWoodward 8237-1600\u003c\/strong\u003e (\u003cstrong\u003e8237-1600\u003c\/strong\u003e Overspeed Detection Device) provides direct electrical execution of triple modular redundant (TMR) speed sensing and safety trip logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8237-1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 23 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.0 in x 17.5 in x 6.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e10 A at 115 VAC \/ 20 A at 220 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles\u003c\/h3\u003e\n\u003cp\u003eThe 8237-1600 utilizes a 2oo3 (two-out-of-three) voted architecture to process MPU and acceleration inputs, ensuring fail-safe execution of turbine shutdown commands. The system manages actuator loop feedback response by integrating MPU-based speed sensing with dedicated 4-20 mA speed readout outputs. To sustain operational integrity in Class 3C2 chemical environments, the electronics utilize conformal coatings resistant to sulfur contamination. Internal thermal heat sink dissipation profiles are optimized for standard cabinet mounting, allowing for online module replacement without compromising the protection logic provided by the remaining two active modules. The interface supports Modbus communication for external status polling while maintaining independent relay-driven trip paths for immediate prime mover isolation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 8237-1600 modules be replaced while the turbine is in operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The triple module design supports online maintenance. A single module can be extracted for repair or replacement while the other two modules continue to monitor speed and execute trip logic.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the internal generator feature in this device?\u003c\/p\u003e\n\u003cp\u003eA: The internal generator allows the system to perform routine speed tests without requiring actual turbine rotation, enabling verification of trip point logic and relay response times during scheduled maintenance periods.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the panel-mount structure is secured to a rigid surface. Verify that the clearance around the 13.0 in x 17.5 in x 6.25 in housing allows for proper airflow and front-plate access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e To maintain the IP56 rating, ensure all cable penetrations and mounting gaskets are correctly seated. Do not expose the unit to environments exceeding the specified 95% humidity limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect MPU sensors to the independent module inputs. Use shielded twisted-pair cables, terminating the shield at the cabinet ground bus to minimize noise interference in the 4-20 mA analog output loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowering:\u003c\/strong\u003e The unit accepts high or low voltage inputs. If utilizing redundant power sources, ensure both inputs are routed through isolated circuit protection to prevent a single power fault from affecting all modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53005301023029,"sku":"8237-1600","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/8237-1600.png?v=1781596999","url":"https:\/\/www.5gplc.com\/products\/8237-1600-protech-gii-overspeed-detection-device-woodward","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}