{"product_id":"80360230-001-honeywell-experion-pks-communications-line-interface-module","title":"80360230-001 | Honeywell Experion PKS Communications Line Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 80360230-001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Communications Line Interface (CLI) within Distributed Control System (DCS) architectures. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule manages the critical data exchange between the central processor and remote Input\/Output racks. Despite the manufacturer's discontinued status, this unit provides a vital lifeline for maintaining legacy system communication without requiring a full-scale control system migration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80360230-001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunications Line Interface (CLI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eData Control System Input \/ Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS Integrated Board \/ Rack Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.43 lbs (0.195 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 80360230-001 eliminates communication bottlenecks between the controller and the field. It prioritizes time-critical process data, ensuring the system maintains real-time control over high-speed loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Legacy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module solves the primary industrial pain point of \"End-of-Life\" (EOL) hardware. It replaces failed interface boards in existing racks instantly, avoiding the massive capital expenditure and downtime associated with upgrading to newer Honeywell series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Mass Design for Vibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWeighing only 0.43 lbs, the board exerts minimal stress on the backplane connectors. This lightweight profile helps the unit withstand the constant mechanical vibrations found in turbine halls or chemical processing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CLI architecture incorporates advanced noise-rejection circuitry. This protects the communication line from electromagnetic interference (EMI) typically generated by nearby high-voltage switchgear or variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Backplane Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe plug-in design ensures a secure electrical path. Technicians can install the module into standard DCS racks with zero field-side wiring changes, simplifying maintenance and reducing the risk of human error during replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle communication faults?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 80360230-001 includes onboard diagnostic indicators. It monitors the health of the communication line and triggers immediate system alarms if data packets drop or signal strength falls below critical thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSince the manufacturer discontinued this model, is this unit reliable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock. It has never seen service and remains in its factory-sealed state, guaranteeing the full operational lifespan and performance of the original Honeywell specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require specific software configuration upon installation?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module typically functions as a transparent interface layer. Once inserted into the correct slot, the host DCS recognizes the hardware and resumes communication based on the existing system configuration, though we recommend verifying node addresses during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary application for the 80360230-001?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers primarily deploy this board in high-density Honeywell DCS environments where stable, long-distance communication between the I\/O processor and the field termination assemblies is non-negotiable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52553603547445,"sku":"80360230-001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/80360230-001.jpg?v=1775793134","url":"https:\/\/www.5gplc.com\/products\/80360230-001-honeywell-experion-pks-communications-line-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}