{"product_id":"7400207-001-triconex-mp2101-tricon-digital-input-module","title":"7400207-001 | Triconex MP2101 Tricon Digital Input Module","description":"\u003ch2\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 7400207-001 (MP2101)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-density digital input interface specifically engineered for the Tricon Triple Modular Redundancy (TMR) platform. It acquires and processes binary signals from field-level hardware such as pressure switches, limit switches, and relay contacts. This module performs critical signal conditioning to ensure that the main safety controller receives accurate, filtered data for executing emergency shutdown (ESD) and safety interlock functions. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original factory stock\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7400207-001 (MP2101)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (Discrete)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Processing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware filtering and galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Interlock \/ Emergency Shutdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.8 cm x 4.5 cm x 18.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.4 kg (Approx. 3.1 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Grade (Standard Operating Temp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe MP2101 filters and isolates incoming digital signals at the hardware level. This eliminates electrical noise and high-frequency interference, preventing transient spikes from triggering nuisance trips in the safety logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Safety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe plug-and-play modular design facilitates rapid installation into the Tricon chassis. This architecture reduces downtime during system expansion or module replacement by utilizing a self-aligning backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized internal processing allows the module to sense state changes with high precision. This ensures the safety system maintains the required response times necessary for SIL 3 (Safety Integrity Level) certification in process control environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Mechanical Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1.4 kg chassis provides superior thermal dissipation and mechanical protection. The compact depth (18.8 cm) allows for installation in standard industrial enclosures while maintaining sufficient airflow between cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 7400207-001 and the MP2101 designation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 7400207-001 represents the specific hardware part number, while MP2101 identifies the functional module series. They refer to the same physical digital input unit used in Tricon systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping during active process control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like most Triconex TMR modules, you can insert or remove the 7400207-001 while the system remains under power. The controller maintains safety logic through redundant modules while you perform the swap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for high-voltage AC inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MP2101 typically handles low-voltage DC signals from field switches. Always verify the specific voltage threshold on your field wiring diagram to ensure compatibility with the module's input circuitry before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":52489790095669,"sku":"7400207-001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/7400207-0011.jpg?v=1774577981","url":"https:\/\/www.5gplc.com\/products\/7400207-001-triconex-mp2101-tricon-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}