{"product_id":"6181x-12a2swx1dc-allen-bradley-versaview-1200x-hazardous-location-industrial-operator-interface","title":"6181X-12A2SWX1DC | Allen-Bradley | VersaView 1200X Hazardous Location Industrial Operator Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e6181X-12A2SWX1DC\u003c\/strong\u003e operates as a ruggedized, extreme-environment industrial operator interface designed for processing zones that require hazardous location certifications. This high-performance hardware platform executes intensive human-machine interface (HMI) visualization, supervisory software tasks, and industrial data logs directly inside volatile manufacturing spaces.\u003c\/p\u003e\n\u003cp\u003eWe supply this computing asset exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed unit\u003c\/strong\u003e. This ensures pristine internal circuit insulation, unblemished capacitive or resistive touch response fields, and factory-fresh component life free from previous deployment stresses or field contamination.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the precise electrical inputs, power consumption metrics, and physical categories for the 6181X-12A2SWX1DC operator interface:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance \u0026amp; Industrial Computing Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6181X-12A2SWX1DC (Alt: 6181X12A2SWX1DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Group\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaView Hazardous Location Series (6181X)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHMI \/ MMI \/ Operator Interface Technology (OIT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18V to 32V DC Continuous Field Power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.79A minimum to 3.28A maximum current draw\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Watts Max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealed Panel Mount Structure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.00 lbs (9.07 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThrives in Class I Division 2 Hazardous Settings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 6181X series hardware incorporates arc-suppressing internal components and non-incendive circuit paths. This specialized construction stops internal electrical sparks or thermal anomalies from igniting volatile atmospheric gases, making it excellent for oil refining, chemical processing, and paint-spray facility floor panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbsorbs Volatile DC Power Surges Safely:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal power supply board accepts a wide 18V to 32V DC input range, handling the voltage drops and inductive spikes caused by heavy industrial generator cycling. This internal conditioning fabric stabilizes the processor clock and display illumination during heavy battery charging or sudden plant power switchovers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRepels Heavy High-Frequency Electromagnetic Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA thick, industrial-grade metal shield wraps the internal processing core and display drive elements. This shielding framework deflects heavy electromagnetic interference (EMI) and radio frequency signals generated by nearby high-horsepower motors, keeping the touch matrix accurate and preventing communication packet loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of power line filtration prevents communication dropouts on this DC model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must route the 18-32V DC power feed through a dedicated, isolated Class 2 power supply unit inside the enclosure. Separate these low-voltage DC power lines from primary high-current AC motor leads by at least 10 inches inside the tracking trays, and always land the chassis ground wire onto a low-impedance copper earth ground bus bar to drain common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 6181X-12A2SWX1DC unit withstand high-pressure water washdowns during facility cleanings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided you mount the interface securely into a NEMA 4X or IP66 rated enclosure cutout. The heavy perimeter compression gasket on the front bezel blocks fine high-pressure water streams and aggressive cleaning solvents from bypassing the panel face, though technicians must protect the exposed rear chassis ports from direct liquid exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 60W power threshold affect adjacent component layout inside a sealed cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt full computing capacity, the unit draws 3.28A and dissipates up to 60W of thermal energy. To avoid localized hot spots that shorten component lifespans, cabinet designers must position the terminal away from heat-producing transformer blocks and leave at least 2 inches of open air gap around the rear ventilation fins to allow natural convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52906255974709,"sku":"6181X-12A2SWX1DC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/6181X-12A2SWX1DC_d052191b-cc03-4554-acc7-2fbb1e5fbd34.png?v=1779258622","url":"https:\/\/www.5gplc.com\/products\/6181x-12a2swx1dc-allen-bradley-versaview-1200x-hazardous-location-industrial-operator-interface","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}