{"product_id":"5x00499g01-32-channel-digital-input-module-emerson","title":"5X00499G01 32-Channel Digital Input Module | Emerson","description":"\u003cp\u003eConfigured for high-density signal acquisition in Ovation control platforms, the \u003cstrong\u003eEmerson 5X00499G01\u003c\/strong\u003e (\u003cstrong\u003e5X00499G01\u003c\/strong\u003e Digital Input Module) provides direct physical execution of discrete status monitoring across 32 independent channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00499G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 5X00499G01 module incorporates advanced channel-to-channel isolation to prevent ground loop interference when interfacing with various field sensors, including limit switches, pressure sensors, and flow meters. In systems where field instrumentation requires secondary diagnostic verification, the module maintains signal integrity compliant with standard process control loops. The isolation architecture ensures that each of the 32 input channels is electrically independent, minimizing the impact of potential field-side faults on the remaining input channels. Cold junction compensation (CJC) is not required for this discrete module, as it is dedicated to digital state detection rather than thermal analog conversion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5X00499G01 module support hot-swapping while the Ovation control system is active?\u003c\/p\u003e\n\u003cp\u003eA: The Ovation I\/O architecture generally supports online module replacement. Ensure that the associated I\/O task is properly inhibited or the channel mapping is verified before removing the module to prevent unintended process state changes or system alarms.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 24 VDC input threshold be adjusted for non-standard signal voltages?\u003c\/p\u003e\n\u003cp\u003eA: No, the input threshold is fixed for standard 24 VDC industrial logic levels. Attempting to use voltage levels outside the specified operating range may result in failure to detect state changes or internal circuitry damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the Ovation I\/O rack slot is clean and free of debris prior to module insertion; align the module with the backplane guides to prevent pin damage.\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring using the appropriate terminal block assembly; ensure proper torque settings to maintain secure connections for all 32 channels.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted-pair cabling for all input signals to minimize electromagnetic interference (EMI) ingress from nearby power cabling.\u003c\/li\u003e\n\u003cli\u003eVerify that the shield drain wire is connected to a common instrument ground point at the cabinet entry, ensuring consistent reference potential across the I\/O system.\u003c\/li\u003e\n\u003cli\u003eConfirm the module status LEDs indicate normal operation upon power-up and verify channel-level status via the Ovation engineering workstation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52952775295285,"sku":"5X00499G01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5X00226G02_cb530dcd-62ec-48f2-bd1b-17a3c62000e4.png?v=1780385102","url":"https:\/\/www.5gplc.com\/products\/5x00499g01-32-channel-digital-input-module-emerson","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}