{"product_id":"5x00226g04-westinghouse-i-o-interface-module","title":"5X00226G04 | Westinghouse | I\/O Interface Module","description":"\u003cp\u003eConfigured for signal management in WDPF and Ovation control platforms, the \u003cstrong\u003eWestinghouse 5X00226G04\u003c\/strong\u003e (\u003cstrong\u003e5X00226G04\u003c\/strong\u003e I\/O Interface Module) provides direct physical execution of I\/O control and signal conditioning across industrial automation networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00226G04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWestinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eChassis-dependent form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC or 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Rack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 5X00226G04 module supports signal conditioning functions necessary for interfacing field devices with legacy Westinghouse WDPF or Ovation DCS architectures. Each module facilitates configurable input\/output point management, allowing for specific analog or digital signal processing as dictated by the system loop requirements. The hardware maintains electrical compatibility with standard process control signals, ensuring channel integrity during high-speed data acquisition. The module design incorporates isolation characteristics to prevent potential ground faults in the field-side loop from impacting the primary control network communication, which utilizes proprietary Westinghouse protocols or standardized RS-485 interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 5X00226G04 be hot-swapped while the DCS rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: Module replacement should be conducted only after inhibiting the associated I\/O points in the engineering workstation software. Confirm the system is not actively executing control logic on the specific channels to prevent process transients during physical removal.\u003c\/p\u003e\n\u003cp\u003eQ: How is the operating voltage (24 VDC vs 125 VDC) configured for this module?\u003c\/p\u003e\n\u003cp\u003eA: The operating voltage is board-specific and determined by the hardware version or internal jumper configuration. Verify the module labeling and system documentation against the field supply voltage before applying power to prevent permanent damage to the I\/O interface circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the rack or module slot power prior to physical installation to ensure circuit protection.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the chassis guide rails and seat the backplane connector firmly to establish the required data and power interface.\u003c\/li\u003e\n\u003cli\u003eTerminate field signal wiring according to the specific loop diagram for the I\/O channel configuration, ensuring all connections are tightened to the terminal strip.\u003c\/li\u003e\n\u003cli\u003eVerify that the shield drain wires for all signal cables are properly connected to the system ground bus to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eConfirm correct module operation by checking the status indicators on the faceplate through the DCS control interface after commissioning the power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52952851644725,"sku":"5X00226G04","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5X00226G02_4d872397-3f77-4eea-bb09-87bc3fc5b373.png?v=1780385537","url":"https:\/\/www.5gplc.com\/products\/5x00226g04-westinghouse-i-o-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}