{"product_id":"5501-376-analog-i-o-module-woodward","title":"5501-376 Analog I\/O Module | Woodward","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 5501-376\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e5501-376\u003c\/strong\u003e Analog I\/O Module, operates as a dedicated hardware component for high-density signal acquisition and proportional actuator control within Woodward processing platforms. Operating with a continuous 5 ms update time, the module interfaces directly with four speed sensors, eight analog inputs, four analog outputs, and two proportional actuator drivers. Software-calibrated circuitry maintains 0.03% full-scale accuracy without requiring physical potentiometers, enabling direct field replacement and deterministic execution of control variables.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5501-376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Sensor Inputs\u003c\/td\u003e\n\u003ctd\u003e4 Channels (Magnetic or Proximity Probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e100-25000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Amplitude\u003c\/td\u003e\n\u003ctd\u003e1-25 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e2000 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 Channels (4-20 mA or 0-5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Driver Outputs\u003c\/td\u003e\n\u003ctd\u003e2 Channels (4-20 mA or 20-160 mA configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.03% full scale, minimum (Software Calibrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response\u003c\/h3\u003e\n\u003cp\u003eThe Woodward 5501-376 Analog I\/O Module incorporates high-speed processing logic designed to optimize actuator loop feedback response within critical governing systems. Executing at a strict 5 ms update rate, the module continuously calculates 100-25000 Hz speed sensor frequency signals against internal setpoints. This low-latency architecture directly commands the two proportional actuator driver outputs (configurable up to 20-160 mA drive strength), minimizing position phase lag and preventing mechanical overshoot during severe transient load corrections on electro-hydraulic fuel valves or steam racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5501-376 module require manual hardware calibration via potentiometers before operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The 5501-376 contains no physical potentiometers. All channel offset, span, and 0.03% full-scale accuracy adjustments are handled strictly via application software, allowing a failed unit to be hot-swapped or replaced with another module of the exact same part number without manual hardware tuning.\u003c\/p\u003e\n\u003cp\u003eQ: What specific field signals are accepted by the four dedicated speed sensor input channels?\u003c\/p\u003e\n\u003cp\u003eA: The four speed inputs accommodate either passive magnetic pickups (variable reluctance) or active proximity probes. The channels process input amplitudes ranging from 1-25 Vrms and frequencies between 100-25000 Hz, with a constant input impedance of 2000 Ohms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSeat the module firmly into the designated control chassis slot, ensuring the backplane connector pins mate completely before engaging the retention levers. Secure the panel mounting screws to establish chassis ground continuity and resist mechanical machine vibration. When terminating field wiring for the speed sensor inputs and analog loops, use shielded twisted-pair cabling exclusively. Connect all signal cable drain shields to the primary cabinet earth ground bus at one end only to prevent ground loop currents from degrading the 12-bit analog input resolution. Route the high-current actuator driver output lines (driving up to 160 mA) in separate wireways away from low-voltage speed inputs to maintain the 500 Vrms isolation rating and suppress electromagnetic cross-talk.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53411350675765,"sku":"5501-376","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5501-376.png?v=1787796146","url":"https:\/\/www.5gplc.com\/products\/5501-376-analog-i-o-module-woodward","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}