{"product_id":"5501-365-woodward-analog-input-output-module","title":"5501-365 | Woodward | Analog Input\/Output Module","description":"\u003cp\u003eConfigured for hydraulic signal regulation in governor control platforms, the \u003cstrong\u003eWoodward 5501-365\u003c\/strong\u003e (\u003cstrong\u003e5501-365\u003c\/strong\u003e Electro-hydraulic Converter) provides direct physical\/electrical execution of electrical-to-hydraulic signal conversion.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5501-365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 50 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response\u003c\/h3\u003e\n\u003cp\u003eThe 5501-365 functions as an interface between electronic control signals and hydraulic actuation. To maintain a stable actuator loop feedback response, the converter utilizes high-precision internal circuitry to minimize deadband and hysteresis in the hydraulic output. The device accepts 24 VDC input power and processes electronic control commands into 0-10 VDC signals to modulate hydraulic servo valve positioning. The RS485 interface allows for remote monitoring of device status and calibration parameters, ensuring that the actuator response remains synchronized with the prime mover governing requirements under transient load conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support real-time adjustments via the RS485 interface?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the RS485 communication interface allows for the monitoring and adjustment of internal calibration parameters. Ensure the master controller protocol matches the module's baud rate and address settings to maintain data communication integrity.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation requirements to ensure thermal stability?\u003c\/p\u003e\n\u003cp\u003eA: The device is rated for operation between -10 deg C and 60 deg C. Ensure the module is mounted in a location with adequate airflow, away from direct thermal radiation sources, to maintain the internal heat sink dissipation profiles within design limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the converter to a rigid, vibration-dampened surface using the designated mounting points on the 100 x 50 x 30 mm chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Wiring:\u003c\/strong\u003e Use shielded twisted-pair cabling for the RS485 communication link and high-current rated wire for the power and signal outputs to prevent voltage drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the module's common reference to the control cabinet's earth bus to mitigate electromagnetic interference and ensure the accuracy of the 0-10 VDC output signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Before applying hydraulic pressure, perform an electrical continuity check and verify the 24 VDC supply. Use a diagnostic tool to confirm the module responds correctly to control commands via the RS485 port.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53002186654005,"sku":"5501-214","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5501-365.png?v=1781511287","url":"https:\/\/www.5gplc.com\/products\/5501-365-woodward-analog-input-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}