{"product_id":"51405098-100-honeywell-totalplant-configured-lcnp4e-interface-card","title":"51405098-100 | Honeywell | TotalPlant Configured LCNP4E Interface Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003e51405098-100\u003c\/strong\u003e operates as a high-throughput LCNP4E (Local Control Network Processor 4 Enhanced) interface card within Honeywell distributed control system (DCS) architectures. This PCI-based hardware board acts as the critical communication bridge, linking operator workstations, engineering nodes, and global user stations directly to the proprietary Local Control Network (LCN). We supply this product as a 100% brand new, factory-original component, ensuring immediate token-ring network synchronization and eliminating data packet loss on your supervisory control bus.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51405098-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCNP4E Interface Card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHost Slot Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard System Expansion Slot (PCI Architecture)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Local Control Network (LCN) \/ TotalPlant Solution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed data bridging and node communication processing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (approx. 4.41 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Original Brand New\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerates Workstation Screen Updates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe enhanced LCNP4E onboard coprocessor offloads communication stack processing from the main workstation CPU. This architecture executes rapid real-time data refreshes, which updates hundreds of dynamic plant graphics, trends, and alarms simultaneously on the operator display without lag.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBlocks High-Frequency Network EMI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultilayer dielectric insulation and integrated gold-plated shielding brackets protect the onboard transceiver components from severe electromagnetic interference (EMI) found inside industrial control server racks. This grounding strategy prevents frame errors and maintains communication uptime even near variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Hot-Standby Node Upgrades:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe physical board configuration aligns perfectly with industrial computer backplane tolerances. This exact structural machining allows field technicians to slide the card smoothly into standard workstation chassis slots, preventing trace scratching and mechanical backplane strain during hardware maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this 51405098-100 LCNP4E card require specific software drivers during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The host computer requires the corresponding version of the Honeywell LCN software subsystem to recognize the LCNP4E co-processing chip. Ensure that your workstation operating system version matches the Honeywell software patch matrix before card installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat handling steps protect the LCNP4E circuit board traces during unboxing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField engineers must wear a grounded electrostatic discharge (ESD) wrist strap at all times when handling this card. Hold the module only by the metal mounting bracket or the non-conductive fiberglass edges to prevent latent component damage from static discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this card include the necessary coaxial connection cables for the LCN tap?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis 100% brand new product includes the core 51405098-100 LCNP4E assembly card inside factory-sealed anti-static packaging. Standard LCN drop cables, transceiver taps, or coaxial network accessories require separate procurement based on your specific cabinet layout lengths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52900014752053,"sku":"51405098-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51405098-100.png?v=1779183905","url":"https:\/\/www.5gplc.com\/products\/51405098-100-honeywell-totalplant-configured-lcnp4e-interface-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}