{"product_id":"51401996-100-honeywell-tdc-3000-eamr-application-module-enhanced-redundancy-card","title":"51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51401996-100 operates as an Enhanced Application Module Redundancy (EAMR) Assembly Card within the legacy TDC 3000 Distributed Control System (DCS) architecture. This hardware add-on board provides high-speed data mirroring and seamless failover synchronization for the primary Application Module (AM). By continuously cross-checking memory states, the card eliminates single-point-of-failure risks in advanced process optimization networks. We supply this product in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original factory condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto secure your plant's data integrity and protect complex control configurations from unexpected hardware failure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Specification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51401996-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoard Identifier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEAMR Assembly Card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCore Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnhanced Redundancy Routing for Application Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLCs \/ Machine Control (PC Board Add-On Board)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell TDC 3000 High-Density Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.07 lbs (0.94 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Sync Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeterministic Real-Time Failover Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnforces High-Speed Fault Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe card establishes an independent, high-bandwidth communication channel between redundant processing pairs. If the primary Application Module crashes, this board executes a deterministic switchover to the backup node in milliseconds, preventing process disruptions in your batch or continuous loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNeutralizes Industrial Cabinet Signal Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-layer board construction and integrated ground shielding insulate the sensitive logic gates from electromagnetic interference (EMI). This heavy-duty shielding guarantees error-free state synchronization even when installed alongside high-current motor starters and switching relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Slide-In Slot Allocation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to slide directly into standard, pre-wired Honeywell TDC 3000 chassis slots, the 2.07 lbs card utilizes native guide rails for mechanical stability. This precise physical alignment prevents terminal pin deformation and minimizes your active installation timeframe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLowers Thermal Loading via Advanced Substrate Layout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe optimized copper layout and upgraded surface-mount components maximize current distribution efficiency. This lowers localized thermal dissipation on the PCB surface, preventing heat pockets from degrading nearby processor modules in sealed NEMA panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this 51401996-100 EAMR board require separate software licenses to activate redundancy features?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board provides the physical hardware layer necessary for enhanced redundancy. Your system must run the appropriate Honeywell TDC 3000 software release that supports Application Module redundancy, and you must configure the corresponding node parameters within the system architecture database.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan field technicians hot-swap this card while the primary Application Module executes process logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Extracting the active EAMR redundancy card breaks the real-time synchronization link and creates a system error configuration state. Always switch your Application Module cluster into an isolated, non-redundant backup configuration or power down the target slot sequence completely before replacing the board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat preventive measures guarantee proper grounding when seating the card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField engineers must clean the chassis guide rails of any accumulated particulate matter or oxidative scale before insertion. Ensure the board slides completely back until the faceplate mounting screws seat firmly into the metal rack frame, establishing a low-impedance ground path to deflect incoming electrical surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52899572515125,"sku":"51401996-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51401996-100.png?v=1779175520","url":"https:\/\/www.5gplc.com\/products\/51401996-100-honeywell-tdc-3000-eamr-application-module-enhanced-redundancy-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}