{"product_id":"51401594-200-honeywell-tdc-3000-kjmp-card","title":"51401594-200 Honeywell TDC 3000 KJMP Card","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51401594-200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51401594-200\u003c\/strong\u003e KJMP Card, operates as a dedicated hardware component for internal bus jumper routing and signal bridging within Honeywell TDC 3000 control system racks. This printed circuit board handles hardware-level jumper settings and inter-board signal routing across backplane slots. Physical connectors interface directly with system racks to maintain signal path continuity and electrical termination without software overhead.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51401594-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15 cm x 8 cm x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (bus powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Type\u003c\/td\u003e\n\u003ctd\u003eKJMP Card (PCB Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Process Manager Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 51401594-200 KJMP board maintains high channel-to-channel isolation parameters to prevent cross-talk and ground loop currents across adjacent backplane signal tracks. Direct galvanic isolation between individual jumper buses isolates high-density logic paths from field-side voltage transients. This isolation architecture prevents noise propagation throughout the rack card cage, ensuring deterministic signal routing across the internal DCS backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 51401594-200 KJMP board support hot-swap insertion during active chassis operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the node or file rack must be completely disconnected before removing or inserting the card to avoid transient electrical faults on the shared backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How are signal termination and jumper positions validated on this card?\u003c\/p\u003e\n\u003cp\u003eA: Jumper configurations are set via physical hardwired pin headers on the board before installation to match specific slot address and signal routing requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What maintains signal integrity across the board edge connectors?\u003c\/p\u003e\n\u003cp\u003eA: Gold-plated edge contacts provide low-resistance connections, while channel isolation prevents interference between adjacent signal traces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all system rack power supplies prior to handling or inserting the PCB card into the card cage.\u003c\/li\u003e\n\u003cli\u003eWear a grounded electrostatic discharge (ESD) wrist strap when handling the board to prevent static damage to surface-mount components.\u003c\/li\u003e\n\u003cli\u003eVerify all physical pin jumper positions on the board match the loop drawings and system slot allocation schematics.\u003c\/li\u003e\n\u003cli\u003eSlide the card into the dedicated rack slot along the guide rails until the card edge connectors seat firmly into the backplane.\u003c\/li\u003e\n\u003cli\u003eTighten retaining hardware to ensure stable grounding contact with the chassis frame.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53620411662645,"sku":"51401594-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51401594-200_Cocoai.png?v=1789962143","url":"https:\/\/www.5gplc.com\/products\/51401594-200-honeywell-tdc-3000-kjmp-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}