{"product_id":"51308047-100-honeywell-touchscreen-interface-cable","title":"51308047-100 Honeywell Touchscreen Interface Cable","description":"\u003cp\u003eConfigured for touchscreen signal transmission in TDC 3000 and Experion PKS control systems, the \u003cstrong\u003eHoneywell 51308047-100\u003c\/strong\u003e (\u003cstrong\u003e51308047\u003c\/strong\u003e Touchscreen Interface Cable) provides direct physical\/electrical execution. It connects Universal Station operator interfaces directly to controller hardware, enabling real-time input processing and system response.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51308047-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.41 lbs (0.19 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard assembly length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive signal conductor (N\/A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eTouchscreen Interface Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Universal Station HMI, TDC 3000, Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eTransmits operator touchscreen input to the control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade assembly with reinforced connector hoods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eWithin Honeywell Experion PKS and legacy TDC 3000 architectures, signal propagation relies on low-noise electrical pathways to prevent data corruption. The 51308047-100 interface cable incorporates internal shielding mechanisms to mitigate electromagnetic interference (EMI) generated by nearby 4-20 mA HART loop wiring, high-density I\/O racks, and switching power supplies. By maintaining low conductor resistance and fixed signal impedance across the touch matrix lines, this assembly limits cross-talk and preserves signal integrity during continuous HMI operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 51308047-100 cable require external power or active signal conditioning?\u003c\/p\u003e\n\u003cp\u003eA: No. The 51308047-100 is a passive physical interconnect designed to route native touchscreen digitizer signals directly between the Universal Station bezel and the processing node.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable assembly be installed or disconnected while the Universal Station is powered?\u003c\/p\u003e\n\u003cp\u003eA: To prevent transient electrostatic discharge (ESD) or digitizer controller communication lockups, power down the display unit or disconnect the associated controller card prior to servicing the cable assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the cable assembly, connector pins, and locking hardware for physical damage or contamination before routing.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through designated control panel raceways, maintaining separation from high-voltage AC power lines and heavy inductive loads to prevent signal disturbance.\u003c\/li\u003e\n\u003cli\u003eAlign the connector pins carefully with the mating port on the Universal Station chassis to avoid bending the internal contacts.\u003c\/li\u003e\n\u003cli\u003eSecure all connector thumbscrews or retaining clips fully to ensure a gas-tight electrical contact and vibration-resistant seat.\u003c\/li\u003e\n\u003cli\u003eVerify that the cable drain wire and outer metallic shield are grounded in accordance with Honeywell system cabinet grounding standards.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53187801153845,"sku":"51308047-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51308051-200_9024808c-b499-4cfc-87a5-2198adbfedc5.png?v=1784530094","url":"https:\/\/www.5gplc.com\/products\/51308047-100-honeywell-touchscreen-interface-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}