{"product_id":"51305418-100-honeywell-tdc-3000-keyboard-cable","title":"51305418-100 Honeywell TDC 3000 Keyboard Cable","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51305418-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51305418-100\u003c\/strong\u003e Industrial Keyboard Cable, operates as a dedicated hardware component for console signal transmission and operator interface interconnectivity within Honeywell TDC 3000 and TPS systems. It routes low-voltage serial data signals between Operator Extension Panels (OEPs), Industrial Keyboards (IKBs), and host node controller interface assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51305418-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Factory Assembly Cable Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded industrial-grade multi-conductor cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Options\u003c\/td\u003e\n\u003ctd\u003eSupports legacy ISA slots or serial port adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Devices\u003c\/td\u003e\n\u003ctd\u003eOperator Extension Panels (OEPs), Industrial Keyboards (IKB12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000, TPS Systems, HBC Cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Integration and Noise Suppression\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51305418-100\u003c\/strong\u003e cable features continuous braided shielding to suppress electromagnetic and radio-frequency interference along the console communication path. When deployed alongside 4-20 mA HART loop protocol marshalling panels and high-density operator workstations, the cable integrity prevents signal degradation during keystroke execution and status LED feedback cycling. The internal conductors are structured to maintain signal rise-time parameters when interfacing directly with HBC cards and system controller nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 51305418-100 cable be connected or disconnected while the console power is active?\u003c\/p\u003e\n\u003cp\u003eA: Hot-plugging serial keyboard cables on legacy control nodes can trigger interface port lockups; it is recommended to de-energize the keyboard assembly or console power prior to reconnection.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required to operate the cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: No. The 51305418-100 is a passive cable harness that routes power and data conductors directly from the host HBC card or serial adapter port to the keyboard interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect cable connectors and strain-relief boots for physical damage before mounting.\u003c\/li\u003e\n\u003cli\u003eAlign the connector pins carefully with the mating socket on the IKB12 assembly or HBC interface card to prevent pin bending.\u003c\/li\u003e\n\u003cli\u003eTighten all connector thumbscrews securely to ensure a low-impedance ground connection through the cable shield.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through designated console wireways, maintaining separation from high-voltage AC lines.\u003c\/li\u003e\n\u003cli\u003eEnsure the cable drain wire is properly bonded to the cabinet chassis ground point.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53191954465077,"sku":"51305418-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51202905-100_f19d448f-1b89-42f0-9d61-b99049567821.png?v=1784622636","url":"https:\/\/www.5gplc.com\/products\/51305418-100-honeywell-tdc-3000-keyboard-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}