{"product_id":"51202902-200-honeywell-shielded-plc-communication-cable","title":"51202902-200 Honeywell Shielded PLC Communication Cable","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51202902-200\u003c\/strong\u003e serves as the primary \u003cstrong\u003e51202902\u003c\/strong\u003e Shielded PLC Communication Cable utilized to execute real-time discrete or analog data transmission across Honeywell distributed control system platforms. The assembly establishes low-impedance physical signal paths through tinned copper conductors to route control bus sequences between processing nodes and terminal panels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51202902-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell International Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eExtended length (typically 5-10 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component (Zero active load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded multi-core industrial communication cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003ePVC\/ XLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding Structure\u003c\/td\u003e\n\u003ctd\u003eAluminum foil with braided shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n\u003ctd\u003e120 ohms +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Jacket\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade protective jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Channel-to-Channel Isolation Parameters\u003c\/h3\u003e\n\u003cp\u003eThe hardware assembly relies on its multi-core PVC\/XLPE dielectric insulation matrix to assist the host architecture in maintaining standardized channel-to-channel isolation limits. Combined with an aluminum foil and braided shield layer, this topology suppresses inductive cross-talk and provides common-mode noise rejection across the 120 ohms transmission line, preventing voltage spikes from degrading loop values.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this communication cable be unlatched while the linked PLC modules are actively running processing loops?\u003c\/p\u003e\n\u003cp\u003eA: No, the connection interface lacks live hot-swap disconnect protection; standard operating protocol requires the related rack power supply to be isolated prior to cable removal to prevent digital bus crashes.\u003c\/p\u003e\n\u003cp\u003eQ: What is the physical limitation imposed by the 120 ohms characteristic impedance?\u003c\/p\u003e\n\u003cp\u003eA: The 120 ohms +-10% characteristic impedance matches standard high-speed serial and differential bus standards, requiring termination resistors at network ends to neutralize data reflections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRoute the shielded multi-core cable through dedicated instrument trays, ensuring physical spacing from high-voltage motor starters or AC switchgear lines to minimize noise induction.\u003c\/li\u003e\n\u003cli\u003eMaintain standard bending radius tolerances during layout routing to prevent elongation of the aluminum foil or deformation of the braided shield structure.\u003c\/li\u003e\n\u003cli\u003eTerminate the integrated shield drain element to a single low-impedance master instrument earth bar within the local panel enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify all terminal clamping hardware matches standard tension requirements to resist ongoing industrial ambient vibration breakdown.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53163963908405,"sku":"51202902-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51202902-200.png?v=1784271470","url":"https:\/\/www.5gplc.com\/products\/51202902-200-honeywell-shielded-plc-communication-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}