{"product_id":"51202901-200-honeywell-wire-harness-assembly","title":"51202901-200 Honeywell Wire Harness Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51202901-200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51202901\u003c\/strong\u003e Wire Harness, operates as a dedicated hardware component for localized point-to-point interface execution within Honeywell distributed control topologies. Configured for low-voltage signal transmission across control enclosures, the 2-wire assembly establishes direct physical connectivity to route discrete inputs, serial communication packets, or internal cabinet bus links between process controllers and termination matrix components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51202901-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMulti-length 2-wire termination profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard control cabinet operational limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution component (Zero active load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e2-wire arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Indicator\u003c\/td\u003e\n\u003ctd\u003e3-3 configuration marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eIndustrial Computer Cable \/ Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Channel-to-Channel Isolation Parameters\u003c\/h3\u003e\n\u003cp\u003eThe hardware routing assembly complies with standard channel-to-channel isolation architecture parameters when integrated into the host cabinet distribution block. By maintaining physical spacing boundaries and structured insulation layers, the 2-wire matrix suppresses adjacent electromagnetic cross-talk, preventing transient induced line distortions from degrading the precision of parallel low-voltage analog loops utilizing the 4-20 mA HART loop protocol.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this wire harness be extracted or replaced while the host system remains online?\u003c\/p\u003e\n\u003cp\u003eA: No, decoupling an active 2-wire communication line or sensor signal path while the controller is live can disrupt the active scanning loop, causing immediate register errors and triggering system interlocks.\u003c\/p\u003e\n\u003cp\u003eQ: How does the physical construction of the conductors mitigate environmental oxidation?\u003c\/p\u003e\n\u003cp\u003eA: The harness uses standard industrial tin or gold plating over its multi-strand copper terminals, minimizing contact resistance degradation in areas subject to thermal shifts and non-condensing moisture variables.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRoute the 2-wire assembly inside designated wireways, ensuring absolute isolation from high-current AC electrical supply trunks to avoid inductive signal noise.\u003c\/li\u003e\n\u003cli\u003eInspect the terminal pins for structural alignment prior to insertion into the controller baseplate socket matrix to prevent pin deformation.\u003c\/li\u003e\n\u003cli\u003eSeat the terminal blocks firmly into position, confirming that the mechanical locking mechanisms are fully engaged to withstand constant industrial vibrations.\u003c\/li\u003e\n\u003cli\u003eVerify that all shield drain wires, if present at the junction terminal interface, are bonded directly to the master instrumentation ground busbar.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53164231721269,"sku":"51202901-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51202901-100_2f4f6baf-96c1-407c-b255-c5f7bf8855cd.png?v=1784277541","url":"https:\/\/www.5gplc.com\/products\/51202901-200-honeywell-wire-harness-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}