{"product_id":"51202329-411-honeywell-link-cable","title":"51202329-411 Honeywell Link Cable","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51202329-411\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51202329\u003c\/strong\u003e Link Cable, operates as a dedicated hardware component for high-speed data transmission within Series C C300 and IOTA platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51202329-411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eLength: 1.5 m (Drop pitch: 12 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical transmission media (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Architecture\u003c\/td\u003e\n\u003ctd\u003eMulti-drop I\/O Link assembly (3-drop layout)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding Structure\u003c\/td\u003e\n\u003ctd\u003eEMI-resistant shielded construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eCustom Honeywell Series C interface headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 51202329-411 cable carries digitized field telemetry between input\/output modules and active C300 controllers, supporting pass-through communication for 4-20 mA HART loop protocol field instruments. Integrated overall metallic shielding provides channel-to-channel isolation from electromagnetic cross-talk and high-frequency noise generated by adjacent cabinet wiring. Low-attenuation twisted conductors preserve signal edge steepness across the 3-drop interface layout to sustain zero-loss data frames during high-density I\/O scan intervals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can individual drop connectors on the 51202329-411 assembly be hot-swapped while the I\/O bus is active?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Individual Series C I\/O modules connected to the cable drops may be hot-swapped without interrupting physical link continuity or signal integrity across remaining active drops on the same bus segment.\u003c\/p\u003e\n\u003cp\u003eQ: What is the effect of exceeding the specified minimum bend radius during cabinet installation?\u003c\/p\u003e\n\u003cp\u003eA: Bending the assembly tighter than its minimum allowed radius deforms internal conductor geometry and damages outer metallic shielding, inducing impedance variations that cause frame errors on the I\/O link.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Engagement\u003c\/strong\u003e: Align the custom connector keying features with the socket on the Input Output Termination Assembly (IOTA) before applying axial force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking Mechanism\u003c\/strong\u003e: Tighten integrated connector retention hardware to ensure low-resistance contact and lock the assembly against cabinet vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Confirm the cable drain wire seats fully through the IOTA ground lug connection to establish single-point ground continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Clearances\u003c\/strong\u003e: Maintain a physical separation of at least 300 mm from high-voltage distribution lines, AC motor wiring, and power switching equipment.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67653490868533,"sku":"51202329-411","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51202329-412_7db7f2c4-1dde-4309-8f18-f2e5acfea0f1.png?v=1791431230","url":"https:\/\/www.5gplc.com\/products\/51202329-411-honeywell-link-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}