{"product_id":"5094-if8-allen-bradley-flex-5000-8-channel-analog-current-voltage-input-module","title":"5094-IF8 | Allen Bradley | FLEX 5000 8-Channel Analog Current\/Voltage Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 5094-IF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog input gateway for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFLEX 5000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform. It provides 8 single-ended channels designed to interface with high-speed process transmitters and sensors. By utilizing dual 24-bit Sigma-Delta analog-to-digital converters, this module delivers elite-level precision and rapid data refresh rates for complex automation architectures. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-sealed integrity for your mission-critical control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFLEX 5000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Single-ended channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 10\\text{V}$\u003c\/span\u003e, \u003cspan class=\"math-inline\"\u003e$0-10\\text{V}$\u003c\/span\u003e, \u003cspan class=\"math-inline\"\u003e$0-5\\text{V}$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$0-20\\text{mA}$\u003c\/span\u003e, \u003cspan class=\"math-inline\"\u003e$4-20\\text{mA}$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigma-Delta (Two 24-bit multiplexed ADC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCalibrated Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$0.05\\%$\u003c\/span\u003e full scale at \u003cspan class=\"math-inline\"\u003e$25\\text{°C}$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScan Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$625\\text{\\mu s}$\u003c\/span\u003e per channel \/ \u003cspan class=\"math-inline\"\u003e$2.5\\text{ms}$\u003c\/span\u003e per module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage: \u003cspan class=\"math-inline\"\u003e$\u0026gt;1\\text{M\\Omega}$\u003c\/span\u003e \/ Current: \u003cspan class=\"math-inline\"\u003e$250\\text{\\Omega}$\u003c\/span\u003e (typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 bits (filter dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$0.31\\text{lbs}$\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e$0.14\\text{kg}$\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-High Precision Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integration of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo 24-bit Sigma-Delta ADCs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the module to resolve minute signal fluctuations. With a voltage resolution as fine as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u0026lt;80 \\mu V\/count\u003c\/strong\u003e, the 5094-IF8 captures highly granular data, making it ideal for precision pressure and flow monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Scan Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module executes a full 8-channel scan in just\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.5 ms\u003c\/strong\u003e. This high-speed performance eliminates latency issues in fast-acting PID loops and ensures your controller receives real-time field data without bottlenecking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial environments often face temperature fluctuations that drift analog readings. The 5094-IF8 maintains an impressive accuracy drift of only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e28 ppm\/ºC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor voltage, ensuring consistent measurements from cold startups to peak operating temperatures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient High Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding 8 channels in a compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.31 lbs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eform factor optimizes cabinet rail space. This high density allows for more I\/O points in a smaller footprint, reducing the need for additional expansion enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 5094-IF8 support mixed current and voltage inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can configure each of the 8 channels independently for either voltage or current via the Studio 5000 Logix Designer software. This flexibility allows you to connect different transmitter types to a single module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle common mode noise between channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports a channel-to-channel common mode voltage of\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 10\\text{V}$\u003c\/span\u003e. This protects signal integrity when field devices operate at slightly different ground potentials, preventing cross-channel interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the Sigma-Delta conversion method in this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSigma-Delta conversion provides excellent noise rejection and high resolution. It effectively filters out high-frequency industrial interference that often plagues standard SAR converters, ensuring a clean signal for your control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a legacy FLEX I\/O module with the 5094-IF8?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5094-IF8 belongs to the FLEX 5000 family, which requires a FLEX 5000 EtherNet\/IP adapter. While it performs similar functions to the 1794 series, it offers significantly higher speeds and resolution and requires the corresponding FLEX 5000 mounting base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52803739058485,"sku":"5094-IF8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5094-IF8.png?v=1777513409","url":"https:\/\/www.5gplc.com\/products\/5094-if8-allen-bradley-flex-5000-8-channel-analog-current-voltage-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}