{"product_id":"5069-l330erms2-allen-bradley-compact-guardlogix-5380-sil-2-safety-controller","title":"5069-L330ERMS2 | Allen-Bradley Compact GuardLogix 5380 SIL 2 Safety Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 5069-L320ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance, multi-discipline processing engine within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. This controller integrates standard control, functional safety, and high-speed motion into a single hardware platform. It provides 3 MB of application memory alongside 1.5 MB of dedicated safety memory to handle complex automation sequences. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock, enabling users to meet\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2 (IEC 61508)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLd (ISO 13849-1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety requirements while managing advanced CIP motion tasks over EtherNet\/IP.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompact GuardLogix 5380\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2 \/ PLd\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 MB Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 MB Dedicated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEtherNet\/IP Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCIP Drive Axes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Axes (Up to 256 Total Motion Axes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 Modules (5069 Compact I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eController Tasks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 Standard Tasks; 1 Safety Task\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbps \/ 1 Gbps (Full Duplex)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-volatile Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 GB (Ships with 1784-SD2 card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet Ports; 1 USB 2.0 Programming Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Core Processing Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069-L330ERMS2 utilizes a multi-core processing architecture to execute safety and standard logic independently. This separation ensures that high-demand standard tasks, such as HMI data polling or complex math, do not interfere with the deterministic execution of the safety task.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Motion on EtherNet\/IP:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller manages up to 16 CIP drive axes directly. It synchronizes servo drives (such as Kinetix 5500 or 5700) over the network, eliminating the need for dedicated motion modules and reducing wiring complexity in high-speed pick-and-place or packaging lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGigabit Networking Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual 1 Gbps Ethernet ports provide the bandwidth required for modern IIoT architectures. The hardware supports Device Level Ring (DLR), Linear, and Star topologies, offering high network resiliency and ensuring that a single cable failure does not halt production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnified Engineering Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStudio 5000 Logix Designer software handles both standard and safety code. This integrated approach allows engineers to use familiar programming languages—Ladder Diagram, Structured Text, and Function Block—to develop safety logic, significantly reducing development time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density I\/O Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller supports up to 31 local 5069 Compact I\/O modules. This high density allows for more field-side terminations in a single rack, saving valuable DIN rail space in compact control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 5069-L330ERMS2 support SIL 3 safety applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific model (MS2) carries a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erating. For applications requiring SIL 3 \/ PLe protection, you must utilize the 5069-L330ERMS3 or a similar SIL 3-rated GuardLogix controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 1.5 MB Safety Memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis dedicated memory space strictly stores the safety-related code and data. It undergoes rigorous internal checks by the controller’s safety core to ensure the logic executes without corruption, providing the \"fail-safe\" reliability required by international safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use older 1769-series Compact I\/O modules with this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 5069-L330ERMS2 requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. The 5069 series utilizes a completely different high-speed backplane and power bus architecture compared to the legacy 1769 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1784-SD2 memory card included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Every\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller ships from the factory with a 2 GB 1784-SD2 SD card installed, facilitating non-volatile project backup and easy firmware updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52532468515125,"sku":"5069-L330ERMS2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5069-L330ERMS2.jpg?v=1775209414","url":"https:\/\/www.5gplc.com\/products\/5069-l330erms2-allen-bradley-compact-guardlogix-5380-sil-2-safety-controller","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}