{"product_id":"5069-ib16-allen-bradley-compact-5000-i-o-16-channel-digital-input-module","title":"5069-IB16 | Allen-Bradley | Compact 5000 I\/O 16-Channel Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital input module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It provides 16 sinking input channels to monitor field-side devices such as sensors, push buttons, and limit switches. Designed for the high-speed backplane of the CompactLogix 5069 series, this module facilitates rapid data acquisition and sub-millisecond response times. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, ensuring your control system maintains factory-certified performance and long-term operational integrity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 5069-IB16 integrates robust electrical parameters to handle diverse industrial signaling:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Sinking Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 32 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 7.4 mA per Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMOD Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA at 18 to 32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSA Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 mA at 10 to 32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Passthrough (MOD\/SA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.55 Amps \/ 9.95 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg (0.31 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-point configuration maximizes I\/O density on the DIN rail, reducing the overall footprint of the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Power Passthrough:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports massive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.55A MOD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.95A SA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epassthrough currents. This capability allows the module to act as a power conduit for downstream I\/O modules, eliminating the need for frequent field power distributor (FPD) modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e250V continuous isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebarrier protects the sensitive backplane logic from field-side electrical noise and transients. This ensures system stability in environments with heavy electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Backplane Sync:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes the high-speed Compact 5000 system clock to timestamp inputs, providing high-resolution data for motion control or precise event-sequence recording.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Heat Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn open-style enclosure design facilitates natural convection cooling, allowing the module to operate at up to 60 °C without requiring auxiliary fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSnap the module onto a standard 35mm DIN rail. Ensure the side-locking tabs engage with the adjacent module to establish the backplane connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD\/SA Power Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the 18-32V DC MOD power for internal logic and the 10-32V DC SA power for field-side devices. Verify that your power supply accommodates the 200 mA SA power requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSinking Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSinking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration; ensure your field devices provide a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSourcing (PNP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutput to complete the circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemovable Terminal Block (RTB):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse a compatible 5069 RTB (sold separately) to facilitate rapid wiring. Tighten terminal screws to the manufacturer-specified torque to prevent loose connections in high-vibration zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 5069-IB16 work with 1769-series CompactLogix controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 5069-IB16 exclusively supports the Compact 5000 I\/O architecture used by 5069-series CompactLogix and GuardLogix controllers. It is not physically or electrically compatible with the 1769 backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between MOD and SA power on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMOD power drives the internal circuitry and communication logic of the module. SA power (Sensor\/Actuator power) supplies the electricity for the field-side inputs and passthrough to the next module in the bank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does the module have such high passthrough current ratings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 9.55A (MOD) and 9.95A (SA) ratings allow engineers to build large I\/O banks. The power flows through the internal bus of the 5069-IB16 to reach other modules, significantly simplifying cabinet wiring by reducing the number of direct power drops needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the terminal block included with the 5069-IB16?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. As is standard for the 5069 series, the Removable Terminal Block (RTB) is a separate component. You must select the appropriate RTB (spring or screw type) based on your specific wiring requirements.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52800706183477,"sku":"5069-IB16","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5069-IB16.png?v=1777444336","url":"https:\/\/www.5gplc.com\/products\/5069-ib16-allen-bradley-compact-5000-i-o-16-channel-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}