{"product_id":"3bur980001r0001-abb-bb512-s800-i-o-bus-backplane","title":"3BUR980001R0001 | ABB BB512 S800 I\/O Bus Backplane","description":"\u003cp\u003eThe \u003cstrong\u003eABB BB512 3BUR980001R0001\u003c\/strong\u003e serves as the primary \u003cstrong\u003eBB512\u003c\/strong\u003e Bus Backplane utilized to execute physical module mounting and signal interconnection across S800 I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBB512 (Product ID: 3BUR980001R0001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.93 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 18SU rack form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C (Standard baseline parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive electrical bus routing distribution matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControl System Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity Allocation\u003c\/td\u003e\n\u003ctd\u003e18 Submodule Units (18SU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Scope\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe internal structural trace alignment of the BB512 backplane is configured to extend the local ModuleBus backbone cluster. By maintaining fixed electrical trace impedance across all 18SU physical slot assignments, the infrastructure prevents signal attenuation and preserves backplane bus communication velocity during peak I\/O scanning sequences. When linked to parent field communication interfaces running on Profinet \/ EtherNet\/IP deterministic networks, the hardware routes parallel discrete and analog registers synchronously. This setup ensures direct firmware flash compatibility for all inserted S800 I\/O modules, supporting expanded multi-channel I\/O density scaling inside the termination cabinet.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BB512 backplane matrix support the live hot-swap insertion of active I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The mechanical and electrical contact design of the 18SU slots permits individual S800 I\/O modules to be hot-swapped while the backplane is powered. However, the master Field Communication Interface (FCI) module or the underlying backplane segment base cannot be unmounted while active logic loops are processing.\u003c\/p\u003e\n\u003cp\u003eQ: What are the passive power consumption boundaries of this backplane assembly?\u003c\/p\u003e\n\u003cp\u003eA: The BB512 operates as a passive electrical bus distribution board containing no onboard microprocessors or active switching logic. It draws 0 W internally; its total current load is defined by the cumulative power draw of the individual I\/O modules inserted into the 18SU slots.\u003c\/p\u003e\n\u003cp\u003eQ: How is backplane bus communication velocity continuity ensured when interconnecting multiple assemblies?\u003c\/p\u003e\n\u003cp\u003eA: The board uses dedicated side-mounted ribbon connector ports to link adjacent backplane segments. These connections maintain continuous internal bus termination parameters across extended cluster footprints to limit signal reflection errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mechanical Realignment:\u003c\/strong\u003e Mount the backplane housing firmly to the internal cabinet structural frame or mounting plates using heavy-duty industrial fasteners. The 2.93 kg net mass must be rigidly braced to neutralize operational floor vibrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Impedance Frame Earthing:\u003c\/strong\u003e Confirm that the integrated metallic grounding plates on the rear of the backplane maintain clear contact with the common cabinet copper earth busbar. Proper grounding is necessary to divert high-frequency electrostatic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubmodule Pin Protection:\u003c\/strong\u003e Align each S800 I\/O module vertically with the guide slots before pressing it into the 18SU interface terminal. Inspect the pin block to ensure no contacts are bent during insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Ventilation Boundaries:\u003c\/strong\u003e Allow a baseline clearance of 50 mm above and below the backplane structure. This spacing ensures unimpeded convective airflow to keep ambient temperatures within the 0 to +55 deg C operational limit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53101874643253,"sku":"BB512 3BUR980001R0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BB5123BUR980001R0001.png?v=1783414626","url":"https:\/\/www.5gplc.com\/products\/3bur980001r0001-abb-bb512-s800-i-o-bus-backplane","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}