{"product_id":"3bdh000395r0001-abb-ci-773f-communication-interface-module","title":"3BDH000395R0001 ABB CI 773F Communication Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB CI 773F 3BDH000395R0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI 773F\u003c\/strong\u003e Communication Interface, operates as a dedicated hardware component for PROFIBUS DP Master protocol execution within Freelance DCS and AC 700F system architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI 773F (3BDH000395R0001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.096 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28 mm x 75 mm x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.6 W (80 mA via CPU 24 VDC terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003e9-pin D-Sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Support\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe CI 773F module manages high-speed PROFIBUS DP Master field bus communications, interfacing directly with local backplane bus communication velocity frameworks to streamline data exchange across Profinet and EtherNet\/IP deterministic networks. Optimized internal transceiver architecture permits maximum I\/O density scaling across distributed remote nodes, while onboard flash memory maintains full firmware flash compatibility during online CPU parameter updates and bus cycle reconfigurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CI 773F module be replaced while the system backplane remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CI 773F supports hot-swap functionality, allowing removal and insertion on an energized local base unit without disturbing CPU backplane operations.\u003c\/p\u003e\n\u003cp\u003eQ: How is primary operating power supplied to the CI 773F interface?\u003c\/p\u003e\n\u003cp\u003eA: Operating power is drawn directly from the 24 VDC terminal of the host CPU module across the backplane, consuming a typical current of 80 mA.\u003c\/p\u003e\n\u003cp\u003eQ: What physical connector standard is required for field bus wiring?\u003c\/p\u003e\n\u003cp\u003eA: Field bus cabling connects through a standard 9-pin female D-Sub connector supporting RS485 differential signaling up to 12 Mbit\/s.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate or verify loop insulation on field bus cables prior to mating the 9-pin D-Sub connector to prevent transceiver damage.\u003c\/li\u003e\n\u003cli\u003eSecure the D-Sub connector retaining screws to ensure continuous ground shield continuity across the metal housing.\u003c\/li\u003e\n\u003cli\u003eVerify proper placement of PROFIBUS DP line termination resistors at both physical ends of the RS485 segment.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 25 mm above and below the module enclosure to permit natural convective heat dissipation under high ambient load conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53253585666357,"sku":"CI 773F 3BDH000395R0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI773F3BDH000395R0001.png?v=1786002326","url":"https:\/\/www.5gplc.com\/products\/3bdh000395r0001-abb-ci-773f-communication-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}