{"product_id":"396572-02-2-emerson-controlwave-digital-output-module","title":"396572-02-2 Emerson ControlWave Digital Output Module","description":"\u003cp\u003eConfigured for discrete field actuation and switching sequence execution in ControlWave PLC platforms, the \u003cstrong\u003eEmerson 396572-02-2\u003c\/strong\u003e (\u003cstrong\u003e396572\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. It interfaces local digital output signals through integrated driver circuitry and incorporates local LED status diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e396572-02-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e396572\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 lbs (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard ControlWave Micro Module Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane Logic Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Diagnostics\u003c\/td\u003e\n\u003ctd\u003eOnboard Local LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eControlWave PLC Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe 396572-02-2 module provides galvanic channel-to-channel isolation across discrete output channels to isolate field-side switching transients from the backplane processing bus. This isolation prevents ground potential differentials and common-mode noise propagation, ensuring stable backplane communication even when deployed in rack assemblies alongside high-density 4-20 mA HART loop protocol analog cards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are channel operating states monitored locally on the 396572-02-2 module?\u003c\/p\u003e\n\u003cp\u003eA: Individual onboard LED indicators display real-time discrete output states and fault conditions directly on the front panel.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 396572-02-2 require external field power for digital output driving?\u003c\/p\u003e\n\u003cp\u003eA: Yes, while logic control is managed by the backplane, field load driving circuits require external DC loop power wired to the module terminal block.\u003c\/p\u003e\n\u003cp\u003eQ: What protection measures exist to prevent electrical noise from feeding back into the system backplane?\u003c\/p\u003e\n\u003cp\u003eA: Integrated optical channel-to-channel isolation barriers decouple the output field side from the internal backplane communication logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure input power to the ControlWave chassis is disconnected prior to inserting or removing the 396572-02-2 module from the rack slot.\u003c\/li\u003e\n\u003cli\u003eAlign the module circuit card with the chassis slot tracks and press firmly until the backplane edge connector seats fully.\u003c\/li\u003e\n\u003cli\u003eTighten the top and bottom retaining screws to secure the module against vibration and establish chassis frame grounding.\u003c\/li\u003e\n\u003cli\u003eRoute field output wiring and external DC power leads through designated cable channels, maintaining physical separation from AC power lines.\u003c\/li\u003e\n\u003cli\u003eConnect all field cable drain shields to a single grounding bus bar inside the enclosure to maintain immunity to transient surges.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53328513466677,"sku":"396572-02-2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/396572-02-2.png?v=1787108723","url":"https:\/\/www.5gplc.com\/products\/396572-02-2-emerson-controlwave-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}