{"product_id":"3625a-digital-output-module-triconex","title":"3625A Digital Output Module | Triconex","description":"\u003cp\u003eConfigured for high-density digital signal control in Tricon safety system platforms, the \u003cstrong\u003eTriconex 3625A\u003c\/strong\u003e (\u003cstrong\u003e3625A\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution of safety-critical output switching via a 32-point commoned interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3625A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to Original Equipment Documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eRefer to Technical Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Tricon module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 13 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e32, commoned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC (16-32 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1,500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy (TMR) Architectural Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTriconex 3625A\u003c\/strong\u003e is engineered for operation within a TMR 2oo3 architecture, ensuring that digital output state execution is governed by a majority-voting mechanism across three independent processor paths. This configuration provides the necessary fault tolerance required for SIL3 certification compliance. The module incorporates 1,500 VDC point isolation to suppress common-mode electrical noise and protect the system backplane from field-side transients. In the event of an internal diagnostic failure or a detected discrepancy between redundant channels, the module initiates fail-safe state execution to ensure that connected valves, solenoids, or alarms revert to a predefined safe state.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3625A module support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 3625A supports hot-swapping within the Tricon chassis. When a replacement module is inserted, it performs an internal power-on self-test and synchronizes output states with the existing redundant modules before transitioning to an operational state.\u003c\/p\u003e\n\u003cp\u003eQ: Are the output points supervised or non-supervised?\u003c\/p\u003e\n\u003cp\u003eA: The 3625A is configured for supervised\/non-supervised digital output operation. Refer to the system software configuration and application logic to verify the specific supervision state of each output point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the chassis slot is properly prepared and free of debris before inserting the 3625A module.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the chassis guide rails and push firmly to ensure full engagement with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eTighten the captive retaining screws on the front panel to provide mechanical stability and ensure electrical grounding of the module chassis.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring connected to the 32-point commoned interface is properly insulated and routed to prevent short circuits.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling where necessary to maintain the integrity of the 24 VDC control loops and minimize electromagnetic interference from high-current field devices.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53031969718581,"sku":"3625A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/3706_9eab36e7-45f7-4c02-bcd0-4f018125c0a6.png?v=1782290648","url":"https:\/\/www.5gplc.com\/products\/3625a-digital-output-module-triconex","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}