{"product_id":"3500-60-05-163179-01-136711-01-bently-nevada-rtd-tc-i-o-module","title":"3500\/60-05 (163179-01 + 136711-01) | Bently Nevada RTD\/TC I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003e3500\/60-05\u003c\/strong\u003e (\u003cstrong\u003e163179-01\u003c\/strong\u003e monitor combined with \u003cstrong\u003e136711-01\u003c\/strong\u003e I\/O module) is a 6-channel temperature monitor designed for the Bently Nevada 3500 machinery protection system. This configuration accepts both Resistance Temperature Detector (RTD) and Thermocouple (TC) inputs, conditioning sensor signals and evaluating them against user-programmable alarm setpoints. It features built-in internal barriers and internal terminations for hazardous area signal integration without recorder outputs.\u003c\/p\u003e\n\u003ch3\u003eArchitecture and Input Processing\u003c\/h3\u003e\n\u003cp\u003eThe module provides six independent temperature monitoring channels that process inputs from standard industrial RTDs and thermocouples. It continuously scales sensor inputs and performs comparison checks against pre-configured Alert and Danger setpoints. This model omits analog recorder outputs, focusing entirely on high-integrity protection and digital rack communication.\u003c\/p\u003e\n\u003ch3\u003eInternal Barriers and Terminations\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration integrates internal safety barriers on a non-isolated circuit layout alongside internal terminations. Field wiring connects directly to the rear module terminals within the rack frame. The internal barrier design limits electrical energy delivered to field sensors, allowing safe placement in hazardous areas when installed with compliant system grounding.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/60-05 (163179-01 + 136711-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD\/TC I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Inputs\u003c\/td\u003e\n\u003ctd\u003eRTD and Thermocouple (TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eInternal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrier Type\u003c\/td\u003e\n\u003ctd\u003eInternal Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003eNone (3500\/60 base monitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What components comprise the 3500\/60-05 order code?\u003c\/p\u003e\n\u003cp\u003eA: It consists of the 163179-01 temperature monitor base board and the 136711-01 I\/O module featuring internal barriers and internal terminations.\u003c\/p\u003e\n\u003cp\u003eQ: Does this module provide analog recorder outputs for each channel?\u003c\/p\u003e\n\u003cp\u003eA: No, the 3500\/60 variant does not include recorder outputs, which are standard on the alternate 3500\/61 series.\u003c\/p\u003e\n\u003cp\u003eQ: Can external termination blocks be used with this internal termination model?\u003c\/p\u003e\n\u003cp\u003eA: No, internal termination I\/O modules wire directly to the rear connector and are incompatible with external termination blocks.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68019230638389,"sku":"3500\/60-05 (163179-01 + 136711-01)","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/350060-05.png?v=1793605837","url":"https:\/\/www.5gplc.com\/products\/3500-60-05-163179-01-136711-01-bently-nevada-rtd-tc-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}